Determining the installation type, Locate the slot where you will install the adapter – Sun Microsystems FASTETHERNET 6U User Manual
Page 47
Chapter 3
Installing the Front-Access Adapter
29
Determining the Installation Type
You can install the adapter in the system in either a hot-swap mode or in a cold-
swap mode. (See “Installation Methods” on page 4 for more information.)
■
Hot swap—see “Installing the Front-Access Adapter in Hot-Swap Mode” on
page 29 for the procedure.
■
Cold swap—see “Installing the Front-Access Adapter in Cold-Swap Mode” on
page 36 for the procedure.
After installing the adapter, see “Connecting the Cables to the Front-Access
Adapter” on page 40 for instructions on connecting the cables.
Installing the Front-Access Adapter in
Hot-Swap Mode
When installing the adapter in a server in hot-swap mode, you must consult the
documentation that shipped with the server. The server’s documentation will
describe the hot-swap commands and system LEDs that will be used when installing
the adapter.
Caution –
Do not use excessive force when installing the adapter into the
CompactPCI slot. You may damage the adapter’s connector or the pins on the
midplane, causing permanent damage to the adapter or to the system. If the adapter
does not seat properly when you apply even pressure, remove the adapter and
carefully reinstall it.
▼
To Install the Front-Access Adapter in Hot-Swap
Mode
The adapter is hot-swap aware, which means the system will recognize the adapter
during the installation.
1. Retrieve the wrist strap from the adapter’s ship kit.
2. Attach the adhesive copper strip of the antistatic wrist strap to the metal chassis of
the system. Wrap the other end twice around your wrist, with the adhesive side
against your skin.
3. Locate the slot where you will install the adapter.