beautypg.com

Sun Microsystems FASTETHERNET 6U User Manual

Page 101

background image

Appendix D

Testing the Adapter

83

The following tests are run when you execute the

test

command:

HME register

MAC internal loopback

100 Mbps PHY loopback

10 Mbps PHY loopback

Note –

To test all of the interfaces of the adapter, you will need to execute the

test

command separately for each

SUNW,qfe

interface.

If all of the tests pass, you will see these messages:

If the adapter’s interface is not connected to a network, you will see the following
error messages:

Note –

If the

test

command fails, verify that the adapter hardware is installed

correctly and the Ethernet device is connected to an active network. If necessary,
replace the adapter or contact your service provider for support.

8. After testing the adapter, type the following commands to return the OpenBoot

PROM to the standard operating mode.

ok test /pci@1f,0/pci@1/pci@1/pci@d/SUNW,qfe@3,1

Hme register test --- succeeded.

Internal loopback test -- succeeded

Transceiver check -- Using onboard transceiver -- Link up passed

ok

ok test /pci@1f,0/pci@1/pci@1/pci@d/SUNW,qfe@3,1

Hme register test --- succeeded.

Internal loopback test -- succeeded

Transceiver check -- Using onboard transceiver -- Link down

Autonegotiation timeout

Check Cable or contact system administrator

Failed

selftest failed. return code = -1

ok

ok setenv diag-switch? false

ok setenv auto-boot? true