beautypg.com

Sun Microsystems Gigabit Ethernet MMF/UTP Adapter User Manual

Page 107

background image

Appendix B

Diagnostic Software

73

4. Set the diag-switch? parameter to true in order to see the diagnostic power-on

self-test (POST) messages.

5. Reset the system to activate these parameter changes.

6. Use the show-nets command to display the list of network devices on the

system.

Among the list of devices, you should see the interfaces specific to the Sun PCI-
Express Dual Gigabit Ethernet Low-Profile adapter you want to test, as shown in the
following example.

Note –

The preceding device paths are examples. The actual device paths on your

system might be different from the examples shown here.

ok setenv diag-switch? true

ok reset-all

ok show-nets

a) /pci@7c0/pci@0/pci@8/network@0,1

b) /pci@7c0/pci@0/pci@8/network@0

c) /pci@7c0/pci@0/pci@2/network@0,1

d) /pci@7c0/pci@0/pci@2/network@0

e) /pci@780/pci@0/pci@8/network@0,1

f) /pci@780/pci@0/pci@8/network@0

g) /pci@780/pci@0/pci@1/network@0,1

h) /pci@780/pci@0/pci@1/network@0

q) NO SELECTION

Enter Selection, q to quit: