Hexadecimal dump

This procedure prints in hexadecimal format all codes (character codes and
control codes) that are sent to the printer by the computer. The printer does not
execute any control codes (such as 0A - linefeed), it just prints them out. The
hexadecimal dump is useful when you are writing programs for printer control.

Make sure that roll paper is loaded in the receipt printer.

Turn off the printer.

While holding down the control panel’s

SLIP/RESUME

button, turn the

printer back on to enter this mode. The printer beeps once to indicate in this
mode.

The printer will now print out the hexadecimal values of any data that is
subsequently sent to it from your computer. The last line buffer should be
flushed by pressing the

RECEIPT

button.

To exit this mode, turn the printer off.

Errors

There are three types of errors:

automatic recovery

errors that clear

automatically after some condition is attained,

recoverable

errors that require

some action by you before they clear, and

non-recoverable

errors that require

servicing by an authorized dealer. If a slip printer error occurs, the

SLIP

indicator flashes quickly. If a receipt printer error occurs, the

RECEIPT

indicator flashes quickly.

Automatic Recovery Error

Error Name

Cause

POWER

Flashing Pattern

Recovery

Head Temperature Error Abnormal thermal head

temperature

Fast

Recovery occurs automatically after
head temperature returns to normal.