SPC3 Hardware Description

2003/04

Copyright (C) Siemens AG 2003. All rights reserved.

Synchronous Motorola-Mode, Processor-Write-Timing

R_W

VALID

Da ta Va lid

AB(10..0)

DB(7..0)

XCS

AS = log.'1'

E_Clock

41

40

42

46

50

51

47

49

48

8.5.5 Timing in the Asynchronous Motorola-Mode (for example, 68HC16) :

In the asynchronous Motorola mode, the SPC3 acts like memory with Ready logic, whereby the access
times depend on the type of accesses.

The request for an access of SPC3 is generated from the positive edge of the AS signal (in addition:
XCS=´0´, R_W=´1´). The request for a write access is generated from the positive edge of the AS signal (in
addition: XCS=´0´, R_W=´0´).

AMI-Vers.

ST-Vers.

No.

Parameter

Min

Max

Min

Max

Unit

60

Address-Setuptime to AS

0

0

ns

61

AS

to Data valid (Zugriff auf RAM)

4T + 5

(88,3)

3T + 45.2

(108)

ns

AS

to Data valid (Zugriff auf die Register)

4T + 18

(101,3)

4T + 22.9

(106,2)

ns

62

Address (AB

10..0

) Holdtime after AS

10

10

ns

63

R_W

Setuptime to AS

10

10

ns

64

AS-Puls-Width (Read)

6T - 10

6T

10

ns

65

Data Holdtime after AS

2

6.3

4

12

ns

66

AS-Inactive-Time

10

10

ns

67

R_W Holdtime after AS

10

10

ns

68

XCS

Setuptime to AS

-5

-5

ns

69

XCS Holdtime after AS

0

0

ns

70

AS

to XDSACK

(Read, Normal Ready)

4T + 5

5T + 14

5T + 16

ns

71

AS

to XDSACK

(Read, Early Ready)

3T + 5

4T + 14

4T + 16

ns

72

XDSACK-Holdtime after AS

4.3

12.7

6

22

ns

73

AS Cycletime

6T

6T

ns

74

Data Setuptime to AS

10

10

ns

75

Data Holdtime after AS

10

10

ns

76

AS-Pulse-Width (Write) *

4T

4T

ns

77

last AS (Read) to XCS

4T + 10

4T + 10

ns

78

XCS to next AS (Write)

2T + 10

2T + 10

ns

79

AS to next AS (Write, XCS don’t care)

6T

6T

ns

Explanations: