beautypg.com

Profibus interface center, Spc3 – Siemens SPC3 User Manual

Page 48

background image

PROFIBUS Interface Center

SPC3

Page 46

V1.3

SPC3 Hardware Description

2003/04

Copyright (C) Siemens AG 2003. All rights reserved.

8.5 Timing Characteristics

The following is generally applicable: All signals beginning with ‘X’ are ‘low active’.
All signal runtimes are based on the capacitive loads specified in the table above.

8.5.1 SYS Bus Interface

Clock Pulse:

No.

Parameter

MIN

MAX

Unit

Clock pulse 48 Mhz :

1

Clock High Time

6.25

14.6

ns

2

Clock Low Time

6.25

14.6

ns

3

Rise Time

4

ns

4

Fall Time

4

ns




Clock Pulse Timing:

1

CLK

2

TCLH

TCLL

2,4V

0,6V

3

4



Distortions in the clock pulse signal are permitted up to a ratio of 40:60. At a threshold of 1.5 or 3.5 V:

Interrupts:

No.

Parameter

MIN

MAX

Unit

1

Interrupt Inactive Time (for EOI_Timebase = 0)

1

1

µ

s

Interrupt Inactive Time

1

1

ms






X/INT 1

EOI



After acknowledging an interrupt with EO1, a min. of 1 us or 1 ms is expected in SPC3 before a new
interrupt is output.