Problem solution, External amplifiers problem solution – Sonance C4630 SE User Manual
Page 53
53
C4630 SE HOME AUDIO SYSTEM
AUDIO
(continued)
Problem
Solution
No audio in zone
a) Are speakers connected?
b) Is zone ON?
c) Is zone volume turned up?
d) Check zone’s M
AXIMUM
V
OLUME
/D
EFAULT
V
OLUME
settings in Sonance Control
Manager software.
No Paging signal in zones.
a) Be sure device’s 12V Page trigger input is connected to C4630 SE’s C
ONTROL
I
NPUT
(see page 16).
b) Be sure Page trigger device is outputting 6 – 24V AC/DC.
c) In an expanded system (multiple C4630 SEs) be sure the Paging audio source
is connected to the P
AGE
IN jack on the primary C4630SE (see page 17).
d) In an expanded system, be sure P
AGE
IN/OUT jacks are connected between
C4630 SEs in an expanded system (see page 17).
No audio in zones driven by secondary a) Be sure the Source Outputs on the primary C4630 SE (the one connected to
C4630 SEs in an expanded system
the source components) are connected to the Source Inputs on the secondary
C4630 SE(s). See page 13.
b) Check the Sonance Control Manager Volume Offset settings for sources on
secondary C4630 SEs (should be ‘0’.) See page 30.
EXTERNAL AMPLIFIERS
Problem
Solution
Keypad or remote V
OLUME
UP/DOWN
a) Make sure the specific Zone F
IXED
/V
ARIABLE
output switch is in the F
IXED
(IN)
commands change volume in all sub-
position (see page 13).
zones when using external multi-
b) Make sure the Zone’s D
EFAULT
and M
AXIMUM
V
OLUMES
are set at their appropriate
channel amplifier for sub-zone
maximum volume in Sonance Control Manager software to achieve proper
expansion
audio level in sub-zones. See page 29.
Keypad or remote V
OLUME
UP/DOWN
Make sure the specific Zone F
IXED
/V
ARIABLE
output switch is in the V
ARIABLE
(OUT)
do not adjust volume when using an
position (see page 13).
external amplifier.