beautypg.com

C4630 se status queries – Sonance C4630 SE User Manual

Page 44

background image

44

C4630 SE HOME AUDIO SYSTEM

Inbound Serial Control of C4630 SEs in Multi-Unit Systems

In systems with multiple C4630 SE units, serial commands in the above format will only control the C4630 SE unit to which
the serial control device is directly connected. However, all of the serial commands in the above table can also be used to
control any C4630 SE in a system with more than one unit, where the serial control device is connected to one ‘Master’
C4630 SE and all of the ‘Slave’ C4630 SEs are connected via their S

YNC

connections (see page 16).

Multi-unit commands have the same format as the single-unit commands, with the addition of the C4630 SE’s Unit ID
number (see page 27) inserted between the opening colon (:) and the command letter.
For example, the V

OLUME

U

P

command for Zone 1 in a single-unit system would be:

::V

V1

1+

++

+<

>

The V

OLUME

U

P

command for Zone 1 of Unit 3 in a multi-unit system would be:

::3

3V

V1

1+

++

+<

>

C4630 SE Status Queries

C4630 SE status queries follow the same format as the serial commands, except that the S

ETTING

is replaced with a

question mark character (?). The response from the C4630 SE will consist of a plus sign (+) followed by the parameter
being checked, the zone (if applicable) and the current setting.

C

Coom

mm

maanndd

SSyynnttaaxx

PPaarraam

meetteerrss

RReessppoonnssee

RR ee ss pp oo nn ss ee PP aa rr aa m

m ee tt ee rr ss

Zone Power

:Zx?

x = Zone 1 – 6

+Zxy

y = 1 if On; y = 0 if Off

Any Zones On

:Z?

None

+Zy

y = 1 if any zone On; y = 0 if all zones Off

Source

:Sx?

x = Zone 1 – 6

+Sxy

y = Current Source (1 – 4)

Volume

:Vx?

x = Zone 1 – 6

+Vxy

y = Current Volume (0 – 60)

Page Volume

:Gx?

x = Zone 1 – 6

+Gxy

y = Current Page Volume (0 – 60)

Mute

:Mx?

x = Zone 1 – 6

+Mxy

y = 1 if Mute On; Y = 0 if Mute Off

Balance

:Bx?

x = Zone 1 – 6

+Bxy

y = Current Balance (-10 – +10)

Bass

:Lx?

x = Zone 1 – 6

+Lxy

y = Current Bass (-8 – +8)

Treble

:Hx?

x = Zone 1 – 6

+Hxy

y = Current Treble (-8 – +8)

The C4630 SE will respond with ‘+ERR’ if the status query is invalid.