C4630 SE HOME AUDIO SYSTEM

Editing IR Commands in the User IR Library
The commands in the U

SER

IR library will almost always

work without editing. However, to get some commands
to work you may need to rename a particular function or
change its IR carrier frequency, the number of times it is
repeated or its sustain characteristic. You can do this in
the IR Library Manager window.
To edit an IR command for a particular remote:
1. Click on that remote in the left-hand window of the

IR L

IBRARY

M

ANAGER

screen.

2. Click on the E

DIT

tab. The remote’s functions will

appear in the main part of the screen (see

Figure 48).

You can change the remote function’s name (not its IR code), its IR frequency, the number of times it is repeated each time a
button is pressed and whether it is to be repeated while the button is held-down. Click on the parameter you want to change
to highlight it and type-in the new value (for R

EPEAT

, check or un-check the box).

NOTE: Typically there should be no reason to change any of these parameters. A component may not

respond to an IR code if you alter any of these parameters to incor rect values.

Adding IR Codes to the User IR Library with the OptiLinQ

®

IR Learner

On occasion, there may be a particular component or command that is not in the U

SER

IR library. You can add IR

commands to the U

SER

IR Library by learning the command using the Sonance OptiLinQ

®

IR Learner (part #92071,

available separately).
1. Open Sonance Control Manager and open the L

IBRARY

menu. Select IR L

IBRARY

M

ANAGER

. The IR L

IBRARY

M

ANAGER

window

(

Figure 46, on page 35) will open.

2. Open the U

SER

.

CML

command library. If the U

SER

.

CML

library does not appear in the window you will have to navigate to it:

a) Open the F

ILE

menu and select O

PEN

. A browser window will appear.

b) Navigate to the S

ONANCE

C

ONTROL

M

ANAGER

program folder. (It will be located in the

P

ROGRAM

F

ILES

folder in your computer’s main hard drive — usually the C: drive.) Double-

click the folder to open it.

c) Double-click the C

OMMAND

L

IBRARIES

folder. The M

ASTER

.

CML

and U

SER

.

CML

libraries will

appear in the window. Select U

SER

.

CML

and click O

PEN

. The U

SER

.

CML

library will now

appear in the IR L

IBRARY

M

ANAGER

window.

3. If you’re adding codes to a remote that’s already in the U

SER

.

CML

library, select it in the left-

hand window. If the remote isn’t in the U

SER

.

CML

library, create a new remote:

a) Open the R

EMOTE

menu and select N

EW

. The C

REATE

N

EW

R

EMOTE

screen (

Figure 49) will appear.

b) Use the drop-down boxes to enter the remote’s manufacturer, type and model. If the

manufacturer, type or model you need don’t appear in the drop-down menus you can type
them in.