C4630 SE HOME AUDIO SYSTEM
C4630 SE Inbound Serial Commands
Each C4630 SE inbound serial command begins with a colon character (:), followed by a single letter that indicates the
desired command, then one or more parameters, and ends with a carriage return (
C
Coom
mm
maanndd
SSyynnttaaxx
PPaarraam
meetteerrss
SSttaattee
C
Coom
mm
meennttss
Zone Power
:Zxy
x = Zone 1 – 6; y = State
1=On; 0=Off
Discrete Zone Setting
All Zones Off
:Zy
y = State
1=On; 0=Off
Global Setting Only
Source Select
:Sxy
x = Zone 1 – 6; y = Source 1 – 4
Adjustable
Discrete Zone Setting
Volume
:Vxyy
x = Zone 1 – 6; yy = Vol 0 – 60
Adjustable
Discrete Zone Setting
Volume Step
:Vx++
++ = increase 1 step
Adjustable
Discrete Zone Setting
:Vx--
-- = decrease 1 step
Adjustable
Discrete Zone Setting
Page Volume
:Gxyy
x = Zone 1 – 6; yy = Vol 0 – 60
Adjustable
Discrete Zone Setting
Page Volume Step
:Gx++
++ = increase 1 step
Adjustable
Discrete Zone Setting
:Gx--
-- = decrease 1 step
Adjustable
Discrete Zone Setting
Mute
:Mxy
x = Zone 1 – 6; y = State
1 = Mute On; 0 = Mute Off
Discrete Zone Setting
Balance
:Bxyyy
x = Zone 1 – 6; yyy = Bal -10 – +10
Adjustable; Center = 0
Discrete Zone Setting
Balance Bump Step
:Bx++
++ = increase 1 step to right
Adjustable
Discrete Zone Setting
:Bx--
-- = increase 1 step to left
Adjustable
Discrete Zone Setting
Bass
:Lxyy
x = Zone 1 – 6 yy = Bass -8 – +8
Adjustable; Flat = 0
Discrete Zone Setting
Bass Bump Step
:Lx++
++ = increase 1 step
Adjustable
Discrete Zone Setting
:Lx--
-- = decrease 1 step
Adjustable
Discrete Zone Setting
Treble
:Hxyy
x = Zone 1 – 6; yy = Treble -8 – +8
Adjustable; Flat = 0
Discrete Zone Setting
Treble Bump Step
:Hx++
++ = increase 1 step
Adjustable
Discrete Zone Setting
:Hx--
-- = decrease 1 step
Adjustable
Discrete Zone Setting
Simulate Button Press
:Pzxyyy
SSeeee SS
II M
M U
U LL A
A TT EE
BB
U
U TT TT O
O N
N
PP
RR EE SS SS
C
C
O
O M
M M
M A
A N
N D
D SS
oonn ppaaggee 4
45
5
After each command is received the C4630 SE will respond with ‘+OK’ if the command is recognized and executed, or
‘+ERR’ if the command is invalid. Note that even valid commands will return ‘+ERR’ if the C4630 SE is not able to process