Sun Microsystems StorageTek L40 User Manual
Page 36
Quick Installation Procedure
1-2
Revision L
96053
3. Remove the packing cushion and foam.
4. Visually inspect the library and drives, using a flashlight if necessary:
CAUTION:
Possible component damage: Make sure you follow the ESD procedure
described in
“ESD-Protection Procedure” on page xxiii
for the next step.
5. Obtain the personality module from the bag taped to the power supply handle and
insert it into its connector at the rear of the library. The library will not initialize properly
unless the personality module is installed.
•
A 20-cell version uses part 31363270x.
•
A 40-cell version uses part 31363300x.
6. If your library is a 20-cell version, attach the cell barrier clip
(
) onto the next to the bottom cell of Column 1. This clip
identifies the cells that you may use for your data cartridges.
7. Connect one end of the power cable into the rear of the library.
8. Connect the other end of the power cable into the wall socket.
9. Power-on the library and drives. The library will begin its initialization routine.
10. When initialization is complete, use the operator panel to configure the library and
drives.
Note: Refer to the user’s guide for any field values that you do not understand.
11. When the configuration is complete, power-off the library and drives.
12. Connect the SCSI cables to the rear of the library.
13. Attach the HVD or LVD label to the SCSI cable connector.
14. Terminate the last drive in the string:
•
HVD uses terminator part 10187075.
•
LVD/SE uses terminator part 10148031.
Note: If your library includes an optional Fibre Channel router, attach cables according
to the figures under
“Connecting Fiber and SCSI Cables” on page 1-16
15. Power-on the library to activate the firmware.
16. Wait for the library to complete initialization.
17. Press the
MENU
button.