B U I LT- I N I N S TA L L AT I O N S P E C I F I C AT I O N S

D O O R C L E A R A N C E

Over-and-Under Models

A

Model ICBBI-30U

794 mm

806 mm Flush Inset

Model ICBBI-30UG

794 mm

806 mm Flush Inset

Model ICBBI-36U

946 mm

959 mm Flush Inset

Model ICBBI-36UG

946 mm

959 mm Flush Inset

Door clearance is based on stainless
steel door and handle dimensions.

O V E R A L L D I M E N S I O N S

Over-and-Under Models

Model ICBBI-30U

W

H

D

762 mm

2138 mm

610 mm

Model ICBBI-30UG with Glass Door

W

H

D

762 mm

2138 mm

610 mm

Model ICBBI-36U

W

H

D

914 mm

2138 mm

610 mm

Model ICBBI-36UG with Glass Door

W

H

D

914 mm

2138 mm

610 mm

Unit dimensions may vary by ± 3 mm.

606 mm

BEHIND

FRAME

WIDTH

OF UNIT

A

Model ICBBI-30U

Model ICBBI-36U

762 mm

2134

mm

762 mm

2134

mm

610 mm

914 mm

2134

mm

914 mm

2134

mm

610 mm

Model ICBBI-30UG

Model ICBBI-36UG

Stainless steel design shown.

I N S T A L L A T I O N S P E C I F I C A T I O N S

Over-and-Under Models —
Overlay (non-flush inset) and Stainless Steel

A

Model ICBBI-30U

749 mm

Model ICBBI-30UG

749 mm

Model ICBBI-36U

902 mm

Model ICBBI-36UG

902 mm

Dimensions are for finished rough openings.

I N S T A L L A T I O N S P E C I F I C A T I O N S

Over-and-Under Models —
Flush Inset Application

A

B

Model ICBBI-30U

749 mm

813 mm

Model ICBBI-30UG

749 mm

813 mm

Model ICBBI-36U

902 mm

965 mm

Model ICBBI-36UG

902 mm

965 mm

Dimensions are for finished rough openings.

1918 mm

178

mm

152

mm

E

LOCATE

ELECTRICAL

WITHIN

SHADED AREA

457 mm

W

LOCATE WATER SUPPLY

WITHIN SHADED AREA

152

mm

FRONT VIEW

SIDE VIEW

2127 mm

OPENING

HEIGHT

A

OPENING WIDTH

76 mm

610 mm

OPENING

DEPTH

13 mm

457 mm*

152

mm

610 mm

OPENING

DEPTH

SHUT-OFF

VALVE

OUTLINE OF

OVERLAY

OR STAINLESS
STEEL MODEL

TOP VIEW

* ANTI-TIP BRACKET MUST NOT
INTERFERE WITH WATER LINE.
REFER TO INSTALLATION
INSTRUCTIONS FOR COMPLETE
DETAILS.

EXTEND WATER LINE APPROX
914 mm FROM BACK WALL.

WATER LINE

1918 mm

178

mm

152

mm

E

LOCATE

ELECTRICAL

WITHIN

SHADED AREA

13 mm

457 mm*

152

mm

610 mm

OPENING

DEPTH

665 mm

FLUSH INSET

DEPTH

SHUT-OFF

VALVE

OUTLINE

OF FLUSH INSET

APPLICATION WITH

19 mm

PANEL

457 mm

W

LOCATE WATER SUPPLY

WITHIN SHADED AREA

152

mm

FRONT VIEW

SIDE VIEW

TOP VIEW

2127 mm

OPENING

HEIGHT

2134

mm

FLUSH

INSET

HEIGHT

6 mm

56 mm**

76 mm

A

OPENING WIDTH

B

FLUSH INSET WIDTH

32

mm

32

mm

56

mm**

610 mm

OPENING

DEPTH

665 mm

FLUSH INSET

DEPTH

* ANTI-TIP BRACKET MUST NOT
INTERFERE WITH WATER LINE.
REFER TO INSTALLATION
INSTRUCTIONS FOR COMPLETE
DETAILS.

**ASSUMES 19 mm PANEL
THICKNESS.

EXTEND WATER LINE APPROX
914 mm FROM BACK WALL.

WATER LINE

6

mm

32

mm

FLUSH INSET

DETAIL

56

mm

610 mm

OPENING

DEPTH