Sun Fire X2100 M2 Server Installation Guide • August 2006

Note –

If you connect to the serial port on the Embedded LOM before it has been

powered on or during its power-on sequence, boot up messages display.

The Embedded LOM eventually displays a login prompt.

login:

5. Log in to the Embedded LOM SP and type the default user name, root, with the

default password, changeme.

Once you have successfully logged in, the Embedded LOM displays its default
command prompt:

SP - ->

6. Do one of the following, depending on whether or not the DHCP server is

present:

Note –

The SP IP address defaults to DHCP. If a DHCP address is not found, the SP

will default to a static IP address.

If no DHCP server is present, run the following commands to assign an IP
address to the Embedded LOM. Fill in the appropriate values for netmask, gateway
and ipaddress.

If a DHCP server is present, the IP information can be obtained running the
following command:

show /SP/AgentInfo

Note –

Be sure to record the IP address assigned to the Embedded LOM.

7. When you apply standby power to the server, the Embedded LOM SP output is

displayed. To launch a console to view the system output, type the following
command:

start /SP/AgentInfo/console

set /SP/AgentInfo NetMask=

netmask

set /SP/AgentInfo Gateway=

gateway

set /SP/AgentInfo DhcpConfigured=disable

set /SP/AgentInfo IpAddress=

ipaddress