To Apply Standby Power for Initial Service
Processor Configuration
Use this procedure to apply standby power to the service processor (SP) before
initial
configuration.
Caution –
Do not operate the server without all fans, component heatsinks, air
baffles,
and the cover installed. Severe damage to server components can occur if
operated
without adequate cooling mechanisms.
1. Connect a grounded AC power cord to the AC power connector on the back panel
of the server and to a grounded AC power outlet.
In standby power mode, the Power/OK LED on the front panel flashes, indicating
that the SP is working. See
and
FIGURE 1-3
Front Panel
2. Continue with initial software setup tasks, as described in Chapter 2.
Note –
At this point, standby power is supplied only to the service processor and power
supply fans. You can proceed to Chapter 2 of this guide to begin initial configuration. Do
not apply main power to the rest of the server until you are ready to install a platform
operating system.