Sharp Digital Laser Copier/Printer AR-5127 User Manual
Page 41
AR-5127 SIMULATION 8 - 13
Operation/procedure
When the [OK] key is pressed, the trouble is canceled.
Operation/procedure
When the [OK] key is pressed, the trouble is canceled.
Operation/Procedure
When the [OK] key is pressed, the trouble is canceled.
Operation/procedure
Enter the adjustment value and press the [OK] key.
Operation/procedure
Counter is displayed.
Operation/procedure
Counter data is displayed.
(Initial screen)
(Executing screen)
14
14-0
Purpose
Clear/Cancel (Trouble etc.)
Function
(Purpose)
Used to cancel excluding the self-diag U2/PF troubles.
Item
Trouble
Error
(Initial screen)
(Process check screen)
16
16-0
Purpose
Clear/Cancel (Trouble etc.)
Function
(Purpose)
Used to cancel the self-diag U2 trouble.
Item
Trouble
Error
(Initial screen)
(Process check screen)
17
17-0
Purpose
Cancel (Trouble, etc)
Function
(Purpose)
Used to cancel the self diag "PF" trouble.
Item
Trouble
Error
(Initial screen)
(Execution check screen)
Sim10 TONER MOTOR
PRESS OK KEY EXEC
Sim10 TONER MOTOR
EXEC
Sim14 TROUBLE CLEAR
TROUBLE CLEAR
(WITHOUT U2,PF)
PRESS OK KEY
Sim14 TROUBLE CLEAR
TROUBLE CLEAR
(WITHOUT U2,PF)
ARE YOU SURE?
Sim16 TROUBLE CLEAR
U2 TROUBLE CLEAR
PRESS OK KEY
Sim16 TROUBLE CLEAR
U2 TROUBLE CLEAR
ARE YOU SURE?
Sim17 TROUBLE CLEAR
PF TROUBLE CLEAR
PRESS OK KEY
Sim17 TROUBLE CLEAR
PF TROUBLE CLEAR
ARE YOU SURE?
21
21-1
Purpose
Setting
Function
(Purpose)
Used to set the maintenance cycle.
Item
Specifications
Counter
Item
Content
Setting range
Default
0
5K (5000 sheets)
0-6
4
1
10K (10000 sheets)
2
20K (20000 sheets)
3
25K (25000 sheets)
4
50K (50000 sheets)
5
80K (80000 sheets)
6
FREE
22
22-1
Purpose
Adjustment/setting/operation data output/check
(display/print)
Function
(Purpose)
Used to check the counter value of each section.
Item
Counter
TOTAL
Total
IMC
IMC counter
MAINTE
Maintenance
DUPLEX
Duplex counter
DEVE
Developer counter
DRUM
Drum counter
OTHERS
The other counters
COPY
Copy counter
FAX SEND
FAX Send counter
PRINTER
Printer counter
FAX RCV
FAX receive counter
22-2
Purpose
Adjustment/setting/operation data output/check
(display/print)
Function
(Purpose)
Used to check the total numbers of misfeed and
troubles. (When the number of misfeed is considerably
great, it is judged as necessary for repair. The misfeed
rate is obtained by dividing this count value with the
total counter value.)
Item
Trouble
Sim21-1 CYCLE SET.
MAINTE CYCLE 0
(0:5 1:10 2:20 3:25
4:50 5:80K 6:FREE)
[ 0- 6]
0
Sim22-1 COUNTER 1/3
TOTAL : nnnnnnn
MAINTE : nnnnnnn
DEVE : nnnnnnn
DRUM : nnnnnnn