Sharp Digital Laser Copier/Printer AR-5127 User Manual
Page 33
AR-5127 SIMULATION 8 - 5
The magnification ratio can be selected in the range of 50% – 200% in
9 steps with
↑
↓
keys.
(AB series) 50
→
70
→
81
→
86
→
100
→
115
→
122
→
141
→
200
(Inch series) 50
→
64
→
77
→
95
→
100
→
121
→
129
→
141
→
200
The scan counter is displayed during execution.
Note: Executable only when the SPF/RSPF is installed.
Operation/procedure
The operations of sensors and detectors in the SPF section are dis-
played.
The active sensors and detectors are highlighted.
Note: Executable only when the SPF/RSPF is installed.
Operation/procedure
The names of the loads which can be operated are displayed. Select
the load to be checked with the 10-key.
The motor for 10sec, the solenoid ON for 500msec, OFF for 500msec.
(20 times)
Note: Executable only when the SPF/RSPF is installed.
Operation/procedure
Used to display the operations of sensors and detectors in the finisher
section.
The active sensors and detectors are highlighted.
Note: Executable only when the finisher is installed.
Operation/procedure
The names of the loads which can be operated are displayed. Select
the load to be checked with the key.
During execution, [EXEC] is highlighted. Under this state, press the
[BACK] key to interrupt the operation.
(Initial screen)
(Input/Selection screen) (Executing screen)
Magnification ratio
50% to 200%
Default
100%
Document size
Varies depending on the destination.
Single/duplex
Selectable only when RSPF is installed, fixed
(single) for SPF.
Set number of times
1 to 999 (0: Continuous operation)
2-2
Purpose
Operation test/check
Function
(Purpose)
Used to check the operation of sensors and detectors
in the SPF unit and the related circuit.
Section
SPF
Item
Operation
EMPS
Empty sensor
DLS1
Tray length sensor (small)
DLS2
Tray length sensor (large)
DWS1
Tray width sensor (small)
DWS2
Tray width sensor (middle)
DWS3
Tray width sensor (large)
FGOD
Paper feed cover sensor
DFD
Document entry detection sensor
RDD
Document exit sensor
OPCLS
Book sensor
2-3
Purpose
Operation test/check
Function
(Purpose)
Used to check the operation of the loads in the SPF
unit and the control circuits.
Section
SPF
Item
Operation
(Initial screen)
(Executing screen)
1:DTM-F
SPF motor forward rotation
2:DTM-R
SPF motor reverse rotation
3:DFSOL
SPF document pick-up solenoid
4:CLH
SPF document exit transport clutch
5:GSOL
RSPF document exit gate solenoid
6:RSOL
RSPF document pressure solenoid
Sim2-1 SPF AGING
115% A3
1SIDE
100%
2SIDE
86%
ZOOM <100%>
0
Sim2-1 SPF AGING
115% A3
1SIDE
100%
2SIDE
86%
ZOOM <100%> EXEC
Sim2-1 SPF AGING
115% A3
1SIDE
100%
2SIDE
86%
ZOOM <100%>
EXEC
Sim2-2 SENSOR CHECK
EMPS
DLS1 DLS2
DWS1 DWS2 DWS3
FGOD
DFD RDD
OPCLS
Sim2-3 OUTPUT CHECK
1:DTM-F 4:CLH
2:DTM-R 5:GSOL
3:DFSOL 6:RSOL
EXEC
2
Sim2-3 OUTPUT CHECK
1:DTM-F 4:CLH
2:
DTM-R
5:GSOL
3:DFSOL 6:RSOL
EXEC
2
3
3-2
Purpose
Operation test/check
Function
(Purpose)
Used to check the operation of sensor and detector in
the finisher and the related circuit.
Section
Sorter/Finisher
Item
Operation
INPD
Finisher paper entry sensor
FWPS
Paper width sensor
JGHP1
Side guide plate HP sensor
JGHP2
Rear edge plate HP sensor
JGPD
Tray paper empty sensor
T1OD
1st tray exit sensor
T1PF
1st tray paper full sensor
PGOP
JAM processing PG open/close detection sensor
T2OD
2nd tray transport sensor
OFHP
Offset HP sensor
T2UP
Tray position sensor (upper)
T2DN
Tray position sensor (lower)
JGDSW
Tray jam processing interlock
EVRE
Lift-up drive control sensor
STHP
Staple HP sensor
READY
Self priming sensor
LSTS
Staple empty sensor
NCTS
Cartridge empty sensor
STND
Staple supply cover open/close sensor
T2PUD
2nd tray upper surface sensor
3-3
Purpose
Operation test/check
Function
(Purpose)
Used to check the operation of the load in the finisher
and the control circuit.
Section
Sorter/Finisher
Item
Operation
(Initial screen)
(Executing screen)
1:JGM1
Side guide plate drive motor
2:JGM2
Rear edge plate drive motor
3:FM-600
Finisher main motor (600dpi)
4:FM-1200
Finisher main motor (1200dpi)
Disabled
5:EVM
Tray lift-up motor
6:OFM
Tray offset motor
7:STM
Staple operation motor
Sim3-2 SENSOR 1/2
INPD FWPS
JGHP1
JGHP2 JGPD T1OD
T1PF
PGOP
T2OD
OFHP T2UP
T2DN
Sim3-3 OUTPUT CHECK
1:JGM1 4:FM-1200
2:JGM2 5:EVM
3:FM-600 6:OFM
1/3 EXEC
Sim3-3 OUTPUT CHECK
7:STM 10:JGSL1
8:
OGSLR
11:JGSL2
9:OGSLL 12:SHTSL
2/3
EXEC
8