beautypg.com

Sharp Digital Laser Copier/Printer AR-5127 User Manual

Page 39

background image

AR-5127 SIMULATION 8 - 11

*1. The negative value of the set value corresponds to the grid high

output voltage.

*2. The set values can be selected from the above 8 patterns only.
*3. The selected pattern determines the grid high voltage and the grid

low voltage.
If, for example, the grid high voltage is set to –480V (pattern 1), the
grid low voltage is –350V.

Operation/procedure
After selecting the mode, enter the adjustment value and press the
[OK] key, and output will be made for 30sec.
The input value is in the increment of –25V.

*1. The negative value of the set value corresponds to the grid high

output voltage.

*2. The set values can be selected from the above 8 patterns only.
*3. The selected pattern determines the grid high voltage and the grid

low voltage.
If, for example, the grid high voltage is set to –480V (pattern 1), the
grid low voltage is –350V.

Operation/procedure
Enter the adjustment value and press the [OK] key, and output opera-
tion is performed for 30sec.

The minimum increment is 2V.
The result of (Set value – 199) / 2 is stored in the EEPROM.
When reading a value from the EEPROM, the value of (EEP value *2)
+ 200 is used as the set value.
Therefore, the set value entered must be an even number. If an odd
number is entered the entered odd number + 1 is displayed after
pressing [OK] key.

Operation/procedure
Enter the adjustment value and press the [OK] key, and output opera-
tion is performed for 30sec.

Display items

Content

Installation

range

Default

1:DENS1(600)

Density 1 (600dpi)

1-8

5 (–580V)

2:DENS2(600)

Density 2 (600dpi)

5 (–580V)

3:DENS3(600)

Density 3 (600dpi)

5 (–580V)

4:DENS4(600)

Density 4 (600dpi)

5 (–580V)

5:DENS5(600)

Density 5 (600dpi)

7 (–630V)

6:TS(600)

Toner save (600dpi)

3 (–530V)

7:DENS1(1200)

Density 1 (1200dpi)

Disabled

8:DENS2(1200)

Density 2 (1200dpi)

Disabled

9:DENS3(1200)

Density 3 (1200dpi)

Disabled

10:DENS4(1200)

Density 4 (1200dpi)

Disabled

11:DENS5(1200)

Density 5 (1200dpi)

Disabled

NO.

Set value

Grid High

Grid Low

1 480

–480V

–350V

2 505

–505V

–375V

3

530

–530V

–400V

4

555

–555V

–425V

5

580

–580V

–450V

6 605

–605V

–475V

7 630

–630V

–500V

8 655 –655V

–525V

8-12

Purpose

Adjustment/Operation test/check

Function
(Purpose)

Used to check and adjust the operation of the main
charger grid voltage (low mode) in each printer mode
and the control circuit.

Section

Image process (Photoconductor/Developing/Transfer/
Cleaning)
Photo conductor

(Initial screen)

(Input/Selection screen) (Executing screen)

Display items

Content

Installation

range

Default

1:DENS1(600)

Density 1 (600dpi)

1-8

5 (–450V)

2:DENS2(600)

Density 2 (600dpi)

5 (–450V)

3:DENS3(600)

Density 3 (600dpi)

5 (–450V)

4:DENS4(600)

Density 4 (600dpi)

5 (–450V)

5:DENS5(600)

Density 5 (600dpi)

7 (–500V)

6:TS(600)

Toner save (600dpi)

3 (–400V)

7:DENS1(1200)

Density 1 (1200dpi)

Disabled

8:DENS2(1200)

Density 2 (1200dpi)

Disabled

9:DENS3(1200)

Density 3 (1200dpi)

Disabled

10:DENS4(1200)

Density 4 (1200dpi)

Disabled

11:DENS5(1200)

Density 5 (1200dpi)

Disabled

Sim8-12 MHV(L) PRT

1:DENS1(600) 3

2:DENS2(600) 5

3:DENS3(600) 5

1/4

Sim8-12 MHV(L) PRT

5:DENS5(600) 7

EXEC [ 1- 8]

7

Sim8-12 MHV(L) PRT

5:DENS5(600) 7

EXEC

[ 1- 8]

7

NO.

Set value

Grid High

Grid Low

1 480

–480V

–350V

2 505

–505V

–375V

3

530

–530V

–400V

4

555

–555V

–425V

5

580

–580V

–450V

6 605

–605V

–475V

7 630

–630V

–500V

8 655 –655V

–525V

8-13

Purpose

Adjustment/Operation test/check

Function
(Purpose)

Used to check and adjust the operation of the
developing bias voltage in FAX mode and the control
circuit.

Section

Image process (Photoconductor/Developing/Transfer/
Cleaning)
Developer/Toner hopper

(Initial screen)

(Executing screen)

Setting range 200-550
Default

426

8-14

Purpose

Adjustment/Operation test/check

Function
(Purpose)

Used to check and adjust the operation of the main
charger grid voltage (high mode) in FAX mode and the
control circuit.

Section

Image process (Photoconductor/Developing/Transfer/
Cleaning)
Photo conductor

(Initial screen)

(Executing screen)

Setting range

1-8

Default

5

Sim8-13 DV BIAS FAX

FAX 426

EXEC [200-550]

4260

Sim8-13 DV BIAS FAX

FAX 426

EXEC

[200-550]

426

Sim8-14 MHV(H) FAX

FAX 5

EXEC [ 1- 8]

5

Sim8-14 MHV(H) FAX

FAX 5

EXEC

[ 1- 8]

5