Table 4: LCD Panel Menu Options in EX3200 and EX4200 Switches (continued)
Description
Menu
The Maintenance menu has the following options to configure and troubleshoot the switch:
■
SYSTEM HALT?—Select this option using the
Enter
button to halt the switch. Press the
Enter
button again
to confirm the halt. Press the
Menu
button to go to the next option in the Maintenance menu.
■
SYSTEM REBOOT?—Select this option using the
Enter
button to reboot the switch. Press the
Enter
button
again to confirm the reboot. Press the
Menu
button to go to the next option in the Maintenance menu.
■
LOAD RESCUE?—Select this option using the
Enter
button to roll back the switch to the rescue
configuration. Press the
Enter
button again to confirm the rollback. Press the
Menu
button to go to the
next option in the Maintenance menu.
■
REQUEST VC PORT?—Select this option using the
Enter
button to configure an uplink module port or an
EX4200-24F network port to be a Virtual Chassis port (VCP) or to delete a VCP from the switch
configuration (when you delete the VCP, the port is reset to an uplink module port or an EX4200-24F
network port).
For information on how to use the REQUEST VC PORT option, see Setting an Uplink Module Port or an
EX4200-24F Network Port as a Virtual Chassis Port Using the LCD Panel.
■
FACTORY DEFAULT?—Select this option using the
Enter
button to restore the switch to the factory default
configuration. Press the
Enter
button again to confirm the restoration. Press the
Menu
button to go to
the next option in the Maintenance menu.
■
ENTER EZSETUP?—Select this option using the
Enter
button to launch EZSetup. Press the
Enter
button
again to confirm the launch. Press the
Menu
button to go to the next option in the Maintenance menu.
You can use the ENTER EZSETUP option only if the switch is in the factory default configuration.
■
EXIT MAINT MENU?—Select this option to exit the Maintenance menu.
You can disable the Maintenance menu in the LCD panel. See “Configuring the LCD Panel Display on EX
Series Switches (CLI Procedure)” on page 166.
MAINT
(Maintenance
Menu)
Related Topics
■
Front Panel of an EX3200 Switch on page 8
■
Front Panel of an EX4200 Switch on page 10
■
Field-Replaceable Units in EX3200 and EX4200 Switches on page 16
■
Connecting and Configuring an EX Series Switch (CLI Procedure) on page 161
■
Connecting and Configuring an EX Series Switch (J-Web Procedure) on page 163
Field-Replaceable Units in EX3200 and EX4200 Switches
Field-replaceable units (FRUs) are components that you can replace at your site. The
field-replaceable units (FRUs) in EX3200 and EX4200 switches are:
■
Power supply
■
Fan tray
■
Uplink module
■
SFP transceiver
16
■
Field-Replaceable Units in EX3200 and EX4200 Switches
Complete Hardware Guide for EX3200 and EX4200 Ethernet Switches