beautypg.com

Juniper Networks JUNOS OS 10.4 User Manual

Page 139

background image

CFM on L2-CE1

[edit interfaces]
ge-0/2/9 {

vlan-tagging;
unit 0 {

vlan-id 2000;

}

}

[edit protocols oam ethernet]
connectivity-fault-management {

maintenance-domain customer {

level 7;
maintenance-association customer-site1 {

continuity-check {

interval 1s;

}
mep 700 {

interface ge-0/2/9.0;
direction down;
auto-discovery;

}

}

}

}

CFM on L2-CE2

[edit interfaces]
ge-1/0/7 {

vlan-tagging;
unit 0 {

vlan-id 2000;

}

}

[edit protocols oam ethernet]
connectivity-fault-management {

maintenance-domain customer {

level 7;
maintenance-association customer-site2 {

continuity-check {

interval 1s;

}
mep 800 {

interface ge-1/0/7.0;
direction down;
auto-discovery;

}

}

}

}

Here are the configurations of CFM on the provider routers.

CFM on PE1

[edit interfaces]
ge-5/0/9 {

vlan-tagging;

119

Copyright © 2013, Juniper Networks, Inc.

Chapter 10: IEEE 802.1ag OAM Connectivity-Fault Management