beautypg.com

JVC VN-C20 User Manual

Page 37

background image

37

A

Action

For specifying the type of action.

Disable

: Do not invoke action.

Mail

: Send via e-mail. Specify the recipient's mail address. The

title of the mail will appear as [Alarm from VN-C20] and the
sender as [Camera ID].

Enter the message to send in [Mail Text]. Input of up to 127
alphanumeric characters or 63 Japanese characters is
allowed. To attach the latest image to the mail, set image
attachment to

AOnB.

FTP

: Send pre-/post-recorded JPEG files via FTP.See Page for

details on pre-/post-recording and FTP server settings.
(

A Page 39)

The maximum transmission rate of FTP is 1 Mbps.If a new
FTP trigger occurs during post-recording, the recorded
portion is treated as pre-recording and a new post-
recording starts.During FTP transmission after finishing
the post-recording, a new post-recording starts if a new
FTP trigger occurs.

TCP

: Send the character string entered in the [TCP/UDP Date]

field to the destinations specified in [TCP/UDP IP Address]
and [TCP/UDP Port Number] via TCP.

UDP

: Send the character string entered in the [TCP/UDP Date]

field to the destinations specified in [TCP/UDP IP Address]
and [TCP/UDP Port Number] via UDP.

TCP/UDP Date

: Input of up to 127 alphanumeric characters.

Output 1 Make

: Change Alarm Output 1 to Make.

Output 2 Make

: Change Alarm Output 2 to Make.

Output 1 Break

: Change Alarm Output 1 to Break.

Output 2 Break

: Change Alarm Output 2 to Break.

Set the alarm output time in the [Alarm Output Duration]
field.

B

1st Trigger

For specifying the first trigger to invoke the action.
Either alarm input (make), alarm input (break) or motion detection can be
selected.

Note:

● When the second trigger is turned off, the action will be invoked by only

the first trigger.

● When motion detection is selected as the first trigger, selection of

AMax.IntervalB and A2nd TriggerB will be disabled.

C

Max.Interval

Valid only when the second trigger is specified.
For specifying the maximum interval between the first and second triggers.
Action will be invoked if the time from invocation of the first trigger to
invocation of the second trigger is within the maximum interval.

D

2nd Trigger

For specifying the second trigger to invoke the action.
Either alarm input (make) or alarm input (break) can be selected. Unlike the
first trigger, motion detection is not available as a choice.

VN-C20_EN.book Page 37 Tuesday, January 31, 2006 1:51 PM