background image

Table 1-9. Service Request Number (SRN) table for SP Switch adapters (continued)

Service Request Number

SRN

source

Failing component(s)

Description

763-200
through
763-299
(except 763-282)

D

ext clock
SPS MX adapter
wrap plug

Problem detected with the
external clock (SP switch).

763-282

D

switch cable

Adapter is good but switch cable
is not attached.

763-2A0
through
763-2A9

D

SPS MX adapter

Problem detected with the
internal clock.

763-3xx
(See note)

D

SPS MX adapter
system or I/O planar

Problem detected with POS
registers.

763-4xx
(See note)

D

SPS MX adapter
software

TBIC test failed.

763-5xx
(See note)

D

SPS MX adapter

SRAM test failed.

763-6xx
(See note)

D

SPS MX adapter

Microprocessor test failed.

763-7xx
(See note)

D

SPS MX adapter

Interrupt test failed.

763-8xx
(See note)

D

SPS MX adapter

FIFO test failed.

763-9xx
(See note)

D

SPS MX adapter
switch cable
system or I/O planar

DMA engine test failed.

763-Ax3
(See note)

D

SPS MX adapter
(terminator)

Card wrap test failed.

763-Ax4
(See note)

D

switch cable
(wrap plug)

Cable wrap test failed.

763-xx2
(See note)

D

SPS MX adapter

Bad adapter (except SRN
763-282).

763-xx3

D

SPS MX Adapter

Bad adapter.

763-xx4

D

SPS MX Adapter
Switch Cable

Bad switch cable.

764-1xx
(See note)

D

SP System Attachment Adapter
software
system or I/O planar

Problem detected with a device
or device data corrupted.
Note: You may need to reinstall
ssp.css software.

764-200
through
764-299
(except 764-282)

D

ext clock
SP System Attachment Adapter
wrap plug

Problem detected with the
external clock (SP switch).

764-282

D

switch cable

Adapter is good but switch cable
is not attached.

SP Switch function (MAP 0620)

Chapter 1. Maintenance Analysis Procedures (MAPs)

1-25