IBM 704 User Manual
Page 256
POST Error Messages
POST Message
Description
0380
ECC SIMM failure, Board in slot #1 SIMM #
Action: Reseat the memory modules on the memory board.
If the problem recurs, have the system serviced.
0392
ECC SIMM failure, Board in slot #2 SIMM #
Action: Reseat the memory modules on the memory board.
If the problem recurs, have the system serviced.
0430
Timer Channel 2 Failure.
Action: Turn off the system and wait 30 seconds; then, turn it
back on. If event logging is enabled, POST logs this
event in nonvolatile flash memory. If the problem
recurs, have the system serviced.
0440
Gate-A20 Failure occurred.
Action: Turn off the system and wait 30 seconds; then, turn it
back on. If the problem recurs, have the system
serviced.
0441
An unexpected interrupt occurred in Protected Mode.
Action: Turn off the system and wait 30 seconds; then, turn it
back on. If the problem recurs, have the system
serviced.
0445
An error occurred in the Master Interrupt Controller.
Action: Turn off the system and wait 30 seconds; then, turn it
back on. If event logging is enabled, POST logs this
event in nonvolatile flash memory. If the problem
recurs, have the system serviced.
0446
An error occurred in the Slave Interrupt Controller.
Action: Turn off the system and wait 30 seconds; then, turn it
back on. If the problem recurs, have the system
serviced.
0450
An error occurred in the Master DMA Controller.
Action: Turn off the system and wait 30 seconds; then, turn it
back on. If the problem recurs, have the system
serviced.
0451
An error occurred in the Slave DMA Controller.
Action: Turn off the system and wait 30 seconds; then, turn it
back on. If the problem recurs, have the system
serviced.
238