Post error message table – IBM 704 User Manual
Page 250
POST Error Messages
POST Error Message Table
The following table shows error messages that might appear on the
screen during the power-on self-test (POST).
Sometimes the first error to occur causes additional errors. In this
case, the system displays more than one error message. Always
follow the suggested action instructions for the first error message
that appears.
POST error codes are also written to the PS/2-standard logging area
in the Extended BIOS Data Area.
POST Message
Description
0002
The primary boot device could not be found.
Action: Make sure that all cables to the device are securely
connected. Start the System Configuration Utility and
check that the first startup device is specified correctly.
If the problem recurs, have the system serviced.
0010
Cache memory failed.
Action: Have the system serviced.
0015
The primary output device could not be found.
Action: Make sure that the cables to the device are securely
attached, and that the device is specified correctly in
the System Configuration Utility. If you find nothing
wrong, but the problem remains, have the system
serviced.
0016
The primary input device could not be found.
Action: Make sure that the cables to the device are securely
attached, and that the device is specified correctly in
the System Configuration Utility. If you find nothing
wrong, but the problem remains, have the system
serviced.
0041
The ID for an EISA device does not match the slot.
Action: Turn off the server, wait 30 seconds; then, turn the
server on again. If the problem recurs, have the system
serviced.
232