Operations

step

3. Set the desired capacity.

• Set the remaining capacity of each device to

output signal.

Call Out Settings

This item is used to output warning signals from the CALL
OUT terminal to the device connected when the capacity be-
comes full or reaches to the specified value.

2

System

4

3

Call Out Settings

Setup Menu

Rear Terminal Setting

step

1. Set the desired capacity for each area.

Off: Does not output a signal.

“Alarm Recording Area” can be set when “Alarm Record-

ing Area” (

page 77 “Change Partition Setting”) is set

to other than “0 %.”

“LPA Recording Area” can be set when “Long Pre-Alarm

Area” (

page 77 “Change Partition Setting”) is set to

other than “0 %.”

Call out settings use the photo-coupler output to decrease

the malfunctions due to wiring. See “CALL OUT output
terminal” (

page 19) for the proper connection.

For the relationship between the warning display and

CALL OUT signal output,

see page 108. The warning

display of the item written “Fixed” in the CALL OUT output
column displays unconditionally. For the item written “Se-
lectable,” you can set the condition to output CALL OUT
signal.

For example, the buzzer can be set to sound when reach-
ing the value set in “Normal Recording Area,” “Alarm
Recording Area,” “LPA Recording Area,” or “Copy 2” while
“Buzzer” is set to “Warning.”

Key Sound

This item is used to make a sound when using the operation-
al buttons, JOG dial, and SHUTTLE ring.

System

4

3

Setup Menu

Rear Terminal Setting

step

1. Set the key sound to on or off.

Buzzer

This item is used for a buzzer to sound when the remaining
main or copy 2 device capacity reaches the value set in “Low
Memory Alarm Setting” (

page 58). Other than the above,

it is possible to set the buzzer to sound when starting alarm
recording or emergency recording or when a warning is dis-
played.

To sound a buzzer only when reaching a specified remaining
HDD capacity:

1) Set “Buzzer” to “Remain.”

2) Set the remaining capacity in “Low Memory Alarm Set-

ting.”

To sound a buzzer when reaching the specified remaining
HDD capacity or when a warning is displayed:

1) Set “Buzzer” to “Warning.”

2) Set the remaining HDD capacity in the “Call Out Settings.”

System

4

3

Setup Menu

Rear Terminal Setting

step

1. Set the desired buzzer setting.

SETTING

BUZZER

Remain

ON

OFF

OFF

OFF

Warning

OFF

ON

OFF

OFF

Alarm

OFF

OFF

ON

OFF

LAN

OFF

OFF

OFF

ON

Off

OFF

OFF

OFF

OFF

When reaching the remaining

capacity set in “Low Memory

Alarm Setting”

When a failure occurs and a

warning is displayed

When an alarm recording or

emergency recording is started

When controlling the buzzer to be

sound via the personal computer

When you set buzzer to “LAN,” the buzzer is controlled

remotely via RS-232C command, etc.

When “Triplex” is set to “Mode 3” or “Mode 5,” buzzer

does not sound. (

page 67.)