Connections

Alarm recording connection

The diagram below shows an example connection for setting alarm signal to sensor number 1.

Alarm switch

[Input condition]
[Input interval]
[Specification]

[Specification]

[Specification]

CALL OUT output terminal

ALARM OUT/MODE OUT 1 to 4/CLOCK ADJ output terminals

EMERGENCY/ALARM IN/REC/CLOCK ADJ input terminals

[Output Circuit]

[Input Circuit]

[Output Circuit]

ground of 200 ms or more
1 second or more
Active: When terminals are short-circuited or “Low” Level is applied.
Non active: Open.

Warning signal (Photo coupler output)
Active: Short

Max. Drive current 7 mA DC.

Non active: Open. Max. Voltage +24 V DC.

Active: “Low” Level Max. Drive current 30 mA DC.
Non active: Open. Max. Voltage +24 V DC.
* Be sure to use these terminals within above rated value.

5V

5V

10kΩ

22kΩ

Input
terminal

0.047µF

GND

4.7kΩ

CALL OUT + terminal

CALL OUT - terminal

Output terminal

GND terminal