Rfc2385 – Manitowoc Ice FLAKE/CHIPLET QF0400 User Manual
Page 91

Section 6
Electrical System
Part No. 80-1214-3
6-29
RFC2385
Initial Start-Up
1B. WATER FILL
After 45 seconds the water float valve
solenoid is energized.
SV2121
RUN
CAPACITOR
(50)
(43)
(48)
COMPRESSOR
RUN
CAPACITOR
(47)
(46)
(49)
(44)
START
CAPACITOR
RELAY
S
C
R
5
2
1
(45)
OVERLOAD
CONTACTOR
CONTACTS
CONTACTOR
CONTACTS
CONTACTOR
COIL
LOW PRESSURE
CUT-OUT
HIGH PRESSURE
CUT-OUT
(96)
(94)
GROUND
L1
L2
COMPRESSOR
CRANKCASE
HEATER
(95)
(74)
FAN MOTOR
(85)
C1
C2
1B. Water Flush (Until Water Contacts Water Level Probe)
High Pressure Control
CLOSED
Low Pressure Control
OPEN
Contactor Coil
OPEN / OFF
Compressor
OFF
Condenser Fan Motor
OFF
Revised 8/2003
This manual is related to the following products: