Refrigeration System
Section 7
7-14
Part No. 80-1214-3
QF2200/RFC2085 REMOTE AIR COOLED
NOTE: These characteristics may vary depending on 24
Hour Ice Production
24 Hour Ice Production
Operating Pressures
QF2300/RFC2385 REMOTE AIR COOLED
NOTE: These characteristics may vary depending on 24
Hour Ice Production
24 Hour Ice Production
Operating Pressures
Air Temp.
Entering
Condenser
°F/°C
Water Temperature °F/°C
50/10.0
70/21.1
90/32.2
70/21.1
2150
1980
1840
80/26.7
2050
1870
1750
90/32.2
1870
1750
1635
100/37.8
1650
1530
1410
110/43.3
1400
1300
1250
Air Temp. Entering
Condenser °F/°C
Freeze Cycle
Discharge
Pressure PSIG
Suction
Pressure PSIG
-20 to 50/
-29 to10.0
220-245
175-185*
14-18
70/21.1
220-250
210-225*
17-21
80/26.7
245-270
18-22
90/32.2
250-275
19-23
100/37.8
315-330
23-26
110/43.3
355-375
25-28
*Headmaster part number 82-5116-3 Only
Air Temp.
Entering
Condenser
°F/°C
Water Temperature °F/°C
50/10.0
70/21.1
90/32.2
70/21.1
2150
1980
1840
80/26.7
2050
1870
1750
90/32.2
1870
1750
1635
100/37.8
1650
1530
1410
110/43.3
1400
1300
1250
Air Temp. Entering
Condenser °F/°C
Freeze Cycle
Discharge
Pressure PSIG
Suction
Pressure PSIG
-20 to 50/
-29 to10.0
175-185
14-18
70/21.1
210-220
19-21
80/26.7
225-265
20-22
90/32.2
250-275
19-23
100/37.8
275-305
21-26
110/43.3
300-340
22-28
Revised 8/2003