Section 6

Electrical System

Part No. 80-1214-3

6-5

Initial Start-Up or Start-Up After
Automatic Shut-Off (cont.)

1B. WATER FILL

After 45 seconds the float valve
solenoid is energized.

SV3034

RELAY

K1

GROUND

L1

L2 (N)

(21)

(65)

CONTACTOR

COIL

(90)

HIGH

PRESSURE

CUT-OUT

(95)

RELAY

K2

RELAY

K3

RELAY K4

(25)

10 AMP

FUSE

(46)

GEARMOTOR

(47)

GEARMOTOR

RUN CAPACITOR

(48)

(43)

(56)

WATER FLOAT

VALVE COIL

(52)

(22)

(55)

(51)

DUMP VALVE

COIL

FAN MOTOR

(AIR-COOLED ONLY)

(10)

(11)

(14)

(41)

CONTACTOR

CONTACTS

L1

T1

RUN

START

(44)

1B. Water Fill (Until Water Contacts Water Level Probe)

Toggle Switch

ICE

Bin Level Probe

Open (No Ice Contact)

Control Board Relays

#1

Contactor Coil

Open / OFF

Compressor

OFF

Condenser Fan Motor

OFF

#2

Dump Valve

OFF

#3

Gear Motor

ON

#4

Water Float Valve Solenoid Coil

ON

Revised 8/2003