Manitowoc Ice FLAKE/CHIPLET QF0400 User Manual
Page 67
Section 6
Electrical System
Part No. 80-1214-3
6-5
Initial Start-Up or Start-Up After
Automatic Shut-Off (cont.)
1B. WATER FILL
After 45 seconds the float valve
solenoid is energized.
SV3034
RELAY
K1
GROUND
L1
L2 (N)
(21)
(65)
CONTACTOR
COIL
(90)
HIGH
PRESSURE
CUT-OUT
(95)
RELAY
K2
RELAY
K3
RELAY K4
(25)
10 AMP
FUSE
(46)
GEARMOTOR
(47)
GEARMOTOR
RUN CAPACITOR
(48)
(43)
(56)
WATER FLOAT
VALVE COIL
(52)
(22)
(55)
(51)
DUMP VALVE
COIL
FAN MOTOR
(AIR-COOLED ONLY)
(10)
(11)
(14)
(41)
CONTACTOR
CONTACTS
L1
T1
RUN
START
(44)
1B. Water Fill (Until Water Contacts Water Level Probe)
Toggle Switch
ICE
Bin Level Probe
Open (No Ice Contact)
Control Board Relays
#1
Contactor Coil
Open / OFF
Compressor
OFF
Condenser Fan Motor
OFF
#2
Dump Valve
OFF
#3
Gear Motor
ON
#4
Water Float Valve Solenoid Coil
ON
Revised 8/2003