Manitowoc Ice FLAKE/CHIPLET QF0400 User Manual
Page 45
Section 3
Ice Machine Operation
Part Number 80-1214-3
3-15
Ice Chute Removal
QC700/QF800
1. Follow steps to remove float reservoir.
2. The ice chute and ice chute grommet will be
removed as a unit. Pull forward on the top of the ice
chute, and slide the ice chute and grommet off the
end of the evaporator spout.
3. Remove evaporator spout insulation.
4. Lift ice chute out of the base.
5. Remove insulation from the bottom of the ice chute.
6. Remove bin level sensor (stainless steel plate) from
ice chute. (Bin level sensor can be disconnected
from the control board for complete removal from
the ice machine.)
NOTE: Clean and sanitize the base and all ice chute
components before reinstalling.
QF2300
1. Place the toggle switch in the OFF position, turn off
the water supply and disconnect electrical power to
the ice machine.
2. Remove ice chute retaining clamp from top of
evaporator.
3. Remove vinyl hose from ice chute spout.
4. Follow steps to remove water reservoir.
5. The ice chute elbow and the ice chute will be
removed separately. Support the ice chute and pull
forward on the elbow to remove.
6. Lift ice chute out of the base, tip bottom forward and
remove bin level sensor (stainless steel plate) from
the top of the ice chute. (Bin level sensor can be
disconnected from the control board for complete
removal from the ice machine.)
7. Remove insulation from ice chute elbow and ice
chute base.
8. Remove evaporator spout o-ring.
NOTE: Clean and sanitize the base, spout and all ice
chute components before re-installing.
2
3
4
5
6
SV2011
SV1787
4
2
5
6
3
8
7