beautypg.com

Manitowoc Ice FLAKE/CHIPLET QF0400 User Manual

Page 76

background image

Electrical System

Section 6

6-14

Part No. 80-1214-3

Automatic Shut-Off

3B. DRAIN EVAPORATOR

To allow water to drain from the
evaporator, the dump valve energizes
for 45 seconds, then de-energizes.

SV3127

RELAY

K1

GROUND

L1

L2 (N)

(21)

(65)

CONTACTOR

COIL

(90)

HIGH

PRESSURE

CUT-OUT

(95)

RELAY

K2

RELAY

K3

RELAY K4

(25)

10 AMP

FUSE

(46)

GEARMOTOR

(22)

(43)

(56)

WATER FLOAT

VALVE COIL

(52)

(22)

(55)

(51)

DUMP VALVE COIL

FAN MOTOR

(AIR-COOLED ONLY)

(41)

CONTACTOR

CONTACTS

L1

T1

C4

POTENTIAL

RELAY

RUN

CAPACITOR

C4

POTENTIAL

RELAY

CONTACTOR

COIL

C4

POTENTIAL

RELAY

C4

POTENTIAL

RELAY

(21)

RUN CAPACITOR

FAN CYCLE

CONTROL

OVERLOAD

COMPRESSOR

(49)

RUN

CAPACITOR

START

CAPACITOR

(31)

(62)

C5

C2

C1

C

R

S

(61)

(45)

3B. Drain Evaporator (45 Seconds)

Toggle Switch

ICE

Bin Level Probe

Closed (Ice Contacting Probe)

Control Board Relays

#1

Contactor Coil

Open / OFF

Compressor

OFF

Condenser Fan Motor

OFF

#2

Dump Valve

OFF

#3

Gear Motor

ON

#4

Water Float Valve Solenoid Coil

OFF

Revised 8/2003

This manual is related to the following products: