Manitowoc Ice FLAKE/CHIPLET QF0400 User Manual
Page 76
Electrical System
Section 6
6-14
Part No. 80-1214-3
Automatic Shut-Off
3B. DRAIN EVAPORATOR
To allow water to drain from the
evaporator, the dump valve energizes
for 45 seconds, then de-energizes.
SV3127
RELAY
K1
GROUND
L1
L2 (N)
(21)
(65)
CONTACTOR
COIL
(90)
HIGH
PRESSURE
CUT-OUT
(95)
RELAY
K2
RELAY
K3
RELAY K4
(25)
10 AMP
FUSE
(46)
GEARMOTOR
(22)
(43)
(56)
WATER FLOAT
VALVE COIL
(52)
(22)
(55)
(51)
DUMP VALVE COIL
FAN MOTOR
(AIR-COOLED ONLY)
(41)
CONTACTOR
CONTACTS
L1
T1
C4
POTENTIAL
RELAY
RUN
CAPACITOR
C4
POTENTIAL
RELAY
CONTACTOR
COIL
C4
POTENTIAL
RELAY
C4
POTENTIAL
RELAY
(21)
RUN CAPACITOR
FAN CYCLE
CONTROL
OVERLOAD
COMPRESSOR
(49)
RUN
CAPACITOR
START
CAPACITOR
(31)
(62)
C5
C2
C1
C
R
S
(61)
(45)
3B. Drain Evaporator (45 Seconds)
Toggle Switch
ICE
Bin Level Probe
Closed (Ice Contacting Probe)
Control Board Relays
#1
Contactor Coil
Open / OFF
Compressor
OFF
Condenser Fan Motor
OFF
#2
Dump Valve
OFF
#3
Gear Motor
ON
#4
Water Float Valve Solenoid Coil
OFF