4-3-8-3. Max Bridge Transmit Delay Bound

Max bridge transmit delay bound (0,1-4 sec): Limits the packets queuing

time in the switch. If enabled, the packets exceeding the queuing time will be

dropped. Press the Space key to set the time. Valid values are 1sec, 2sec,

4sec and Off. The default is 1 second when this feature is enabled. This

setting does not depend on what values are set in the “Priority Configuration”

menu.

Enable Delay Bound: If this parameter is enabled, the “Max bridge transmit

delay bound” must also be configured. This item allows you to limit queuing

time of the low priority packets in the switch. When the low priority packets

exceed the “Max Delay Time” they will be transmitted. Press the Space key to

enable or disable this function. By default the Enable Delay Bound is set to

OFF.

Max Delay Time: Set the time that low priority packets are queued in the

switch. The valid range is 0 to 255 ms. Since the default is OFF, the Max

Delay Time is 0. This item must be set if “Enable Delay Bound” is

configured.

NOTE: “Max bridge transmit delay bound control” must be enabled before

Max Delay Bound is enabled.