SPECIFICATIONS

43

Operating
status

Selection can be made from output frequency, motor current (steady or peak value), output
voltage, frequency setting, running speed, motor torque, converter output voltage (steady or
peak value), electronic overcurrent protection load factor, input power, output power, load
meter, motor exciting current, cumulative energization time, actual operation time, watt-hour
meter, regenerative brake duty and motor load factor.

Display on
operation panel
FR-DUO4 or
parameter unit
FR-PU04

Alarm
definition

Alarm definition is displayed when protective function is activated. 8 alarm definitions are stored.
(Four alarm definitions are only displayed on the operation panel.)

Operating
status

Input terminal signal states, output terminal signal states, option fitting status, terminal
assignment status

Alarm
definition

Output voltage/current/frequency/cumulative energization time

immediately before protective function is activated

Di

sp

la

y

Additional
display on
parameter unit
(FR-PU04)
only

Interactive
guidance

Operation guide and troubleshooting by help function

Protective/alarm functions

Overcurrent shut-off (during acceleration deceleration, constant speed) regenerative
overvoltage shut-off, undervoltage, instantaneous power failure, overload shut-off (electronic
overcurrent protection), ground fault overcurrent, stall prevention, overload warning, fin
overheat, option error, parameter error, PU disconnection, No. of retries over, output open
phase, CPU error, 24VDC power supply output short circuit, operation panel power supply short
circuit, main circuit error

Ambient temperature

(1)

10

°

C to +40

°

C (non-freezing)

Ambient humidity

90%RH or less (non-condensing)

Storage temperature

(2)

20

°

C to +65

°

C

Ambience

Indoors. (No corrosive and flammable gases, oil mist, dust and dirt.)

E

nvi

ronm

ent

Altitude, vibration

Max. 1000m (3280.80 feet) above sea level, 5.9m/s

2

{0.6G} or less (conforms to JIS C 0911)

Note: 1. For FR-A540L-375K, 450K at constant torque (CT) rating maximum ambient temperature can be

50

°

C (122

°

F).

2. Temperature applicable for a short period in transit, etc.