PARAMETERS

20

Func-

tion

Parameter

Number

Name

Setting Range

Minimum

Setting

Increments

Factory Setting

Refer To

Page:

107

V/F4 (fourth frequency voltage)
(Note 1)

0 to 1000V

0.1V

0

98

108

V/F5 (fifth frequency) (Note 1)

0 to 400Hz, 9999

0.01Hz

9999

98

5-point

f

lex

ible V/

F

ch

ar

acte

risti

cs

109

V/F5 (fifth frequency voltage)
(Note 1)

0 to 1000V

0.1V

0

98

110

Third acceleration/deceleration time

0 to 3600 sec/

0 to 360 sec, 9999

0.1 sec/

0.01 sec

9999

99

111

Third deceleration time

0 to 3600 sec/

0 to 360 sec, 9999

0.1 sec/

0.01 sec

9999

99

112

Third torque boost (Note 1)

0 to 30.0%, 9999

0.1%

9999

99

113

Third V/F (base frequency) (Note 1)

0 to 400Hz, 9999

0.01Hz

9999

99

*114

Third stall prevention operation current

0 to 150%

0.1%

150%

99

115

Third stall prevention operation frequency

0 to 400Hz

0.01Hz

0

99

T

hird f

unc

tions

116

Third output frequency detection

0 to 400Hz, 9999

0.01Hz

9999

99

117

Station number

0 to 31

1

0

99

118

Communication speed

48, 96, 192

1

192

99

119

Stop bit length/data length

0, 1 (data length 8)

10, 11 (data length 7)

1

1

99

120

Parity check presence/absence

0, 1, 2

1

2

99

121

Number of communication retries

0 to 10, 9999

1

1

99

122

Communication check time interval

0, 0.1 to 999.8 sec,

9999

0.1

0<9999>

99

123

Waiting time setting

0 to 150ms, 9999

10ms

9999

99

C

om

m

unic

at

ion f

unc

tions

124

CR, LF presence/absence selection

0,1,2

1

1

99

128

PID action selection

10, 11, 20, 21

1

10

109

129

PID proportional band

0.1 to 1000%, 9999

0.1%

100%

109

130

PID integral time

0.1 to 3600 sec, 9999

0.1 sec

1 sec

109

131

Upper limit

0 to 100%, 9999

0.1%

9999

109

132

Lower limit

0 to 100%, 9999

0.1%

9999

109

133

PID action set point for PU operation

0 to 100%

0.01%

0%

109

PI

D

c

ont

rol

134

PID differential time

0.01 to 10.00 sec, 9999

0.01 sec

9999

109

135

Commercial power supply-inverter
switch-over sequence output terminal
selection

0, 1, 2

1

0

116

136

MC switch-over interlock time

0 to 100.0 sec

0.1 sec

1.0 sec

116

137

Start waiting time

0 to 100.0 sec

0.1 sec

0.5 sec

116

138

Commercial power supply-inverter
switch-over selection at alarm occurrence

0, 1

1

0

116

C

om

m

erc

ial pow

er s

upply

-

in

ve

rt

er

sw

itch

-o

ve

r

139

Automatic inverter-commercial power
supply switch-over frequency

0 to 60.00Hz, 9999

0.01Hz

9999

116

140

Backlash acceleration stopping
frequency (Note 7)

0 to 400Hz

0.01Hz

1.00Hz

119

141

Backlash acceleration stopping time
(Note 7)

0 to 360 sec

0.1 sec

0.5 sec

119

142

Backlash deceleration stopping
frequency (Note 7)

0 to 400Hz

0.01Hz

1.00Hz

119

B

ackl

as

h

143

Backlash deceleration stopping time
(Note 7)

0 to 360 sec

0.1 sec

0.5 sec

119

Di

sp

la

y

144

Speed setting switch-over

0, 2, 4, 6, 8, 10, 102,

104, 106, 108, 110

1

4

119

*148

Stall prevention level at 0V input

0 to 150%

0.1%

120%

58

Addit

ional

func

tions

*149

Stall prevention level at 10V input

0 to 150%

0.1%

150%

58