PARAMETERS

19

Func-

tion

Parameter

Number

Name

Setting Range

Minimum

Setting

Increments

Factory Setting

Refer To

Page:

52

DU/PU main display data selection

0, 5 to 14, 17, 18, 20,

23, 24, 25, 100

1

0

67

53

PU level display data selection

0 to 3, 5 to 14, 17, 18

1

1

67

54

FM terminal function selection

1 to 3, 5 to 14,

17, 18, 21

1

1

67

55

Frequency monitoring reference

0 to 400Hz

0.01Hz

60Hz<50Hz>

69

D

isp

la

y fu

ncti

on

s

56

Current monitoring reference

0 to 3600A

0.1A

Rated output current

69

57

Restart coasting time

0 to 30 sec, 9999

0.1 sec

9999

70

A

uto

ma

tic

res

ta

rt

func

tions

58

Restart cushion time

0 to 60 sec

0.1 sec

1.0 sec

70

Addit

ional

fu

ncti

on

59

Remote setting function selection

0, 1, 2

1

0

72

60

Intelligent mode selection

0 to 8

1

0

73

61

Reference I for intelligent mode

0 to 3600A, 9999

0.1A

9999

75

*62

Ref. I for intelligent mode accel.

0 to 150%, 9999

0.1%

9999

75

*63

Ref. I for intelligent mode decel.

0 to 150%, 9999

0.1%

9999

75

64

Starting frequency for elevator mode

0 to 10Hz, 9999

0.01Hz

9999

75

65

Retry selection

0 to 5

1

0

76

66

Stall prevention operation level reduction
starting frequency

0 to 400Hz

0.01Hz

60Hz<50Hz>

77

67

Number of retries at alarm occurrence

0 to 10,101 to 110

1

0

76

68

Retry waiting time

0 to 10 sec

0.1 sec

1 sec

76

69

Retry count display erasure

0



0

76

70

Special regenerative brake duty

0 to 100%

0.1%

0%

77

71

Applied motor

0 to 8, 13 to 18

1

0

78

72

PWM frequency selection

0, 1, 2

1

1

79

73

0-5V/0-10V selection

0 to 5, 10 to 15

1

1

80

74

Filter time constant

0 to 8

1

1

81

75

Reset selection/disconnected PU
detection/PU stop selection

0 to 3, 14 to 17

1

14

81

76

Alarm code output selection

0, 1, 2, 3

1

0

83

77

Parameter write disable selection

0, 1, 2

1

0

84

78

Reverse rotation prevention selection

0, 1, 2

1

0

85

Operat

ion s

elec

tion f

unc

tions

79

Operation mode selection

0 to 8

1

0

86

80

Motor capacity

0 to 3600kW, 9999

0.1kW

9999

89

81

Number of motor poles

2, 4, 6, 12, 14, 16, 9999

1

9999

89

82

Motor exciting current (Note 6)

0 to , 9999

1

9999

90

*83

Rated motor voltage

0 to 1000V

0.1V

575V

90

84

Rated motor frequency

50 to 120Hz

0.01Hz

60Hz<50Hz>

90

89

Speed control gain

0 to 200%

0.1%

100%

89

90

Motor constant (R1) (Note 6)

(Note 6)

(Note 6)

9999

90

91

Motor constant (R2) (Note 6)

(Note 6)

(Note 6)

9999

90

92

Motor constant (L1) (Note 6)

(Note 6)

(Note 6)

9999

90

93

Motor constant (L2) (Note 6)

(Note 6)

(Note 6)

9999

90

94

Motor constant (X) (Note 6)

(Note 6)

(Note 6)

9999

90

95

Online auto tuning selection

0, 1

1

0

96

Mo

to

r co

nsta

nt

s

96

Auto tuning setting/status

0, 1, 101

1

0

90

100

V/F1 (first frequency) (Note 1)

0 to 400Hz, 9999

0.01Hz

9999

98

101

V/F1 (first frequency voltage)
(Note 1)

0 to 1000V

0.1V

0

98

102

V/F2 (second frequency) (Note 1)

0 to 400Hz, 9999

0.01Hz

9999

98

103

V/F2 (second frequency voltage)
(Note 1)

0 to 1000V

0.1V

0

98

104

V/F3 (third frequency) (Note 1)

0 to 400Hz, 9999

0.01Hz

9999

98

105

V/F3 (third frequency voltage) (Note 1)

0 to 1000V

0.1V

0

98

5-point

f

lex

ible V/

F

ch

ar

acte

risti

cs

106

V/F4 (fourth frequency) (Note 1)

0 to 400Hz, 9999

0.01Hz

9999

98