Main circuit error [e,15] details, Protective functions – MITSUBISHI ELECTRIC FR-A500L User Manual
Page 38
PROTECTIVE FUNCTIONS
27
Main circuit error [E,15] details
A500
CHARGE
ALARM
Left LED
Right LED
There are two 7-segment LEDs on the
right of the operation panel as shown on
the right. The following fault details are
indicated by the LED display.
Brake unit
cooling fin
overheating
Control
board
ambient
temperature
error
Output
overcurrent
Cooling
fan power
supply
error
Capacitor
overcurrent
Cooling fin
overheat
Gate power
supply
error
For example, if the display is
, the output overcurrent , capacitor overcurrent and gate power supply
errors have occurred.
Name
Details
Brake unit cooling fin overheating
The inverter output will stop if the brake unit's cooling fin temperature rises above the
specified value.
Control board ambient temperature error
The inverter output will stop if the ambient temperature of the control board rises above
the specified value.
Output overcurrent
The inverter output will stop if the inverter's output current flows above the specified
value.
Cooling fan power supply error
The inverter output will stop if the cooling fan's power drops below the specified value.
Capacitor overcurrent
The inverter will stop if a current exceeding the specified value flows to the main circuit
smoothing capacitor.
Cooling fin overheat
The inverter output will stop if the cooling fin's temperature rises above the specified
value.
Gate power supply error
The inverter output will stop if the gate power supply voltage drops below the specified
value.