INSTALLATION AND WIRING

13

(3) Changing the control logic

The input signals are set to sink logic for the NA version, and to source logic for the EC version.
To change the control logic, the connector on the back of the control circuit terminal block must be moved to
the other position.
(The output signals may be used in either the sink or source logic independently of the connector position.)
1) Loosen the two mounting screws in both ends of the control circuit terminal block. (The screws cannot be

removed.)
With both hands, pull down the terminal block from the back of the control circuit terminals.

2) Remove the connector in the sink logic position on the back surface of the control circuit terminal block and

fit it to the source logic position.

SINK

CON3

CON2

SOURCE

SINK

CON3

CON2

SOURCE

NA version

SINK

CON3

CON2

EC version

SOURCE

3) Using care not to bend the pins of the control circuit connector, reinstall the control circuit terminal block

and fix it with the mounting screws.

Note: 1. Make sure that the control circuit connector is fitted correctly.

2. While power is on, never disconnect the control circuit terminal block.
3. The sink-source logic change-over connector must be fitted in only one of those positions. If it is

fitted in both positions at the same time, the inverter may be damaged.