beautypg.com

2 response delay in refresh system, Response delay in refresh system – MITSUBISHI ELECTRIC 700 Series User Manual

Page 75

background image

70

I/O Processing Method

3.6.2

Response delay in refresh system

This section describes a delay of an output change in response to an input change.
An output change in response to an input change has a delay of up to two scans as
shown in Fig. 2.6.

Fig 3.7 Output Y Change in Response to Input X Change

Ladder example

When Y1E turns on earliest

The Y1E output turns on earliest when the control input terminal turns from OFF to

ON immediately before a refresh. X5 turns on at an input refresh, Y1E turns on at

step 0, and the control output terminal turns on at an output refresh after execution of

the END instruction.

In this case, therefore, a delay of a control output terminal change in response to a

control input terminal change is one scan.

When Y1E turns on latest

The Y1E output turns on latest when the control input terminal turns from OFF to ON

immediately after a refresh. X5 turns on at the next input refresh, Y1E turns on at

step 0, and the control output terminal turns on at an output refresh after execution of

the END instruction.

In this case, therefore, a delay of a control output terminal change in response to a

control input terminal change is two scans.

In this ladder, output Y1E turns on when input
X5 turns on.

OFF

OFF

OFF

ON

ON

ON

OFF

ON

Input refresh

Input refresh

Output refresh

0 END

END

0 56

0

(Minimum 1 scan)

Control output
terminal

Y1E

X5

Control input
terminal

Delay

OFF

OFF

OFF

ON

ON

ON

OFF

ON

Input refresh

Input refresh

Output refresh

0 END

END

0 56

0

Delay

(Maximum 2 scans)

Control output
terminal

Y1E

X5

Control input
terminal