beautypg.com

11 paluse train input function – MITSUBISHI ELECTRIC 700 Series User Manual

Page 45

background image

40

Paluse train input function

1.11 Paluse train input function

Pulse train (the number of sampling pulses) from terminal JOG is stored to D9236.
When the sampling pulses overflow, make adjustment with the setting of Pr. 416 and
Pr. 417.

The number of sampling pulses
= the number of input pulses per count cycle x Pre-scale setting value (Pr. 417) x
increments scaling factor (Pr. 416)

Parameter

Name

Initial
Value

Setting

Range

Description

291

Pulse train input

selection

0

0, 10,20

Terminal JOG

1,11,21,100 Pulse train input

416

Pre-scale function

selection

0

0 to 5

Pre-scale function selection
(increments scaling factor)
0: No function
1:

Ч1

2:

Ч0.1

3:

Ч0.01

4:

Ч0.001

5:

Ч0.0001

417

Pre-scale setting

value

1

0 to 32767

Set the pre-scale value to calcute the

number of sampling pulse when

inputting the pulse train.

Device No.

Name

Setting

Range

Description

D9236

Pulse train input sampling
pulse

0 to 32767

The number of pulses counted in
count cycle is stored.

D9237

Pulse train input cumulative
count value L

0 to

99999999

The cumulative value of the number
of sampling pulses is stored.

D9238

Pulse train input cumulative
count value H

D9239

Reset request of pulse train
input count

0

Not clear

1

Count clear

D9240

Count start of the pulse train
input

0

Stop counting

1

Start counting