beautypg.com

5 setting list of built-in plc function parameter, Setting list of built-in plc function parameter – MITSUBISHI ELECTRIC 700 Series User Manual

Page 14

background image

9

Function Block Diagram

1

P

L

C

FU

N

C

TI

O

N

1.5.5

Setting list of built-in PLC function parameter

The built-in PLC function parameters are designed to specify the ranges of using the

PLC function, e.g. program capacity, device assignment and various functions.

Item

GX Developer Default

Setting Range

Sequence program
capacity

6k steps

1k step

File register capacity

None

Cannot be set (default)

Comment capacity

None

Cannot be set (default)

Status latch

None

Cannot be set (default)

Sampling trace

None

Cannot be set (default)

Microcomputer program
capacity

None

Cannot be set (default)

Latch range setting

L1000 to L2047

Cannot be set (invalid if set)

Link range setting

None

Cannot be set (default)

I/O assignment

None

Cannot be set (default)

Internal relay, latch relay,
step relay setting

M0 to 999

L1000 to 2047

None for S

L and S cannot be set.
(Operates as M if set)

Watchdog timer setting

200ms

10 to 2000ms

Timer setting

100ms: T0 to 199

10ms: T200 to 255

(100ms timers since only T0 to 7

are available)

16 points for 100ms, 10ms and
retentive timers. Timers have
consecutive numbers.

Counter setting

Without interrupt counters

Cannot be set (default)

Remote run/pause

None

Can be set using X0 to 1F.
Otherwise invalid. Pause does not
function.

Error-time operation mode

Fuse blow: Continued

Setting invalid (since there are no
fuses)

I/O verify error: Stop

Setting invalid
(since there are no I/O modules)

Operation error: Continued

Stop/Continued

Special function module check

error: Stop

Setting invalid (since there are no
special modules)

STOP

→ RUN output mode

Operation status prior to

STOP is re-output.

Prior to STOP/after operation
execution

Print title registration

None

Cannot be set

Keyword registration

None

Online setting cannot be made but
parameter setting is valid.

REMARKS

•The following functions are not supported.

1. Constant scan, 2. Latch (device data backup for power failure), 3. Pause,

4. Status latch, 5. Sampling trace, 6. Offline switch

•If parameter clear of the inverter is performed, the above built-in PLC function parameters are

not cleared.

•For the built-in PLC function parameter setting operation, refer to the GX Developer

Operating Manual.