Output 2 relays (Dry contacts: N.O./N.C./Com.)

Relay Strike Time 01~99 seconds or Toggle Mode (00) / Relay 1 (*100) , Relay 2 (*200)

Relays Electric Current 3A/120VAC , 3A/24VDC

Relay Activation Time

Strike Time: 1~99 seconds(adjustable)
Strike mode: Access Timer or Latch

Memory Volume

49+50 PIN codes

Relay 1 is controlled by 001~049 user slots
Relay 2 is controlled by 050~099 user slots

EPROM

Non-volatile memory, System will retain all programs and codes after a total
loss of power.

Finish Stainless steel brushed housing

Ambient Humidity 0~95% relative humidity non-condensing

Operating Temperature -20°C~+70°C


3. The indicator signal chart:

Sound and LED indicator:

Green LED

Power on, stand-by

Red LED

Relay 1 activated

LED signal

Yellow LED

Relay 2 activated

1 Beep

Effective PIN codes

2 Beeps

Entering 、Exiting from the programming mode

3 Beeps

Incorrect operation

Sound signal

5 Beeps

Master Code reset to Factory default (12345)


4. Operation Instruction:

Enter Program Mode:

1. Compose twice the master code (Factory default is 「12345」)

→ 2 beeps → you are now in the "program mode".

2. After 60 seconds if you have not entered any codes or data, the system will

automatically exit from the programming mode. After 32 wrong codes attempts at ,
system the will be lockout for 60 seconds.

Exit from the programming mode:

1. Press「#」 to exit from the programming mode.

Add PIN codes (at programming mode)

Enter the slot position code 「*001~*099」→????? Input 5 digit PIN code→ (beep)
enrolled (repeat), or,
Press 「#」 to exit from the programming mode.

Note 1:

The codes「00000」,「12345」or master code can not be used as PIN code.

Note 2:

Relay 1 is controlled by 001~049 user slots, Relay 2 is controlled by 050~099

user slots


To Delete a User Code:(at programming mode)

Press the slot position code of your choice to delete (example "006") →Press「*006」

→「00000」→(beep)→delete→Press「#」 to exit from the programming mode.