Calibrating angle gauge, About service – Grizzly G0564 User Manual
Page 33

Model g0563/g0564 (Mfg. since 10/11)
-31-
calibrating angle
Gauge
in order to maintain accuracy and precision with
the oscillating edge sander, periodically calibrate
the angle gauge.
tools needed:
Machinist's square ............................................ 1
straight slot screwdriver ................................... 1
to calibrate the angle gauge:
1. loosen the angle adjustment lock handle.
2. place the machinist's square on the table and
press it against the platen.
3. adjust the platen until it is flush with the
machinist's square as in
figure 35.
figure 35. aligning the table to the platen
4. tighten the angle adjustment lock handle.
5. loosen the angle indicator pin screw, shown
in
figure 36, a
1
/
2
turn.
always
disconnect
power to the machine
before performing ser-
vice adjustments. failure
to do this may result in
serious personal injury.