c. Insert the jumper into 2-3

3. Clear all PINs:

a. Reset Master Code to default value (5 beeps, clearing all PINs)

b. Insert the jumper into 2-3


 Enter Setting Mode

Enter the master code twice (Default value: “1234” or “12345) to enter setting mode (2 beeps)

Note: 1. After 60 seconds if no data entered, it will automatically exit the setting mode.

2. The controller will be locked for 60 seconds upon 30 consecutive master codes

attempt.


 Add new PINs (In setting mode)

1. Enter Master code twice (2 beeps)
2. Slot position *01~*21
3. Enter the PINs (1 beep)
4. Repeat, or press “#” to exit setting mode


Relay 1 is controlled by the slot position *01~*20
Relay 2 is controlled by the slot position *21
Note: “00000”, “1234”, “12345” and master code cannot be used for PINs.


Set the Relay Strike Time (In setting mode)

1. Enter the master code twice (2 beeps)
2. Press *30 (or *31)
3. Press 05 (01~99) (1 beep)

Press 05 will set the relay strike to 5 seconds, relay set to toggle mode by press “00”

4. Press “#” to exit setting mode
Note: In Toggle mode, the relay will switch between N.C. contact and N.O. contact by input

PIN once.


 Delete PINs (In setting mode)

1. Enter the master code twice (2 beeps)
2. Press *06 (e.g. code to delete)
3. Press 0000 (or 00000) (1 beep)
4. Press “#” to exit setting mode


 Change Master Code (In setting mode)

1. Enter the master code twice (2 beeps)
2. Press*00
3. Enter new master code (1 beep)

4. Press “#” to exit setting mode