Enter Program Mode

:

1. Compose twice the master code (Factory master is 「12345」)→ (2 beeps), LED: yellow →

"programming mode"

2. Attention:

z

If the system is not entered any codes or data in 60 seconds, it will exit from the programming
mode automatically.

z

After 30 wrong codes attempts to enter the master code, the lockout facility will operate for 60
seconds. (Keypad flashes with blue back light)

‹

Exiting from the program mode

:

Press「#」 to exit from the programming mode.

‹

Add PIN codes

Enter the Programming modeÆ Enter the slot position code 「*001~*099」Æ (beep)Æ????? (Enter
5 digital PIN codes) Æ (beep) ÆEnrolled.
Please repeat the procedure to set another user PIN code.
Press 「#」 to exit from the programming mode, or program other operating.

Remarks:

The codes「00000」、「1234」、or master code「12345」are not used to be PIN code.

‹

To Set Time delay for Opening door

„

Enter the Programming modeÆ「*100」Æ (beep)Æ01~99 ( Pressing 05 represents for 5
seconds)Æ ( 2 beeps)ÆEnrolled.
Press 「#」 to exit from the programming mode, or program other operating.

„

Press 00 for the time delay to be “Latch mode”: The first time PIN codes are entered, the relay
changes from N.C. to N.O. (Red LED lights up); The second time PIN codes are entered, the
relay changes from N.O. to N.C. (Red LED extinguished)

‹

To Delete a User Code

Enter the Programming mode→ Press the slot position code of your choice to delete (e.g. "06")
→Press「*006」→ (beep)Æ「00000」→ (beep) →deleted
Press「#」 to exit from the programming mode, or programming other operating.

‹

Changing the Master codes

Enter the Programming modeÆ Enter「*000」Æ (beep)ÆPress the 5 digits to be the new master
code→(beep)→Enrolled
Press 「#」 to exit from the programming mode, or program other operating.

‹

Master Code reset to default value 12345,

Insert the jumper RESETÆ 1-2 positionÆ (5 beeps)Æreset successfullyÆ Insert the jumper to 2-3
positions to back to normal operation mode.

Remarks: The occupied PIN codes can’t be the master codes.