Gianni Industries GEM DG-100 User Manual
Page 3

Copyright © Gianni industries, inc. All Rights Reserved.
P-MU-DG100-4C Ver. D Published on 2009.12.02 Page: - 3 -/ 4
Set the Relay Strike Time (In setting mode)
1. Press *100
2. Press 05(01~99)(1 beep)
Press 05 will set the relay strike to 5 seconds, relay set to toggle mode
3. Press “#” to exit setting mode
In Toggle mode, the relay will switch between N.C. contact and N.O. contact upon enter PIN once.
Delete PINs (In setting mode)
1. Press *006 (e.g. code to delete)
2. Press 0000(1 beep)
3. Press “#” to exit setting mode
Change Master Code (In setting mode)
1.Press *000
2. Enter 4-digit new master code (1 beep)
3. Press “#” to exit setting mode
Master Code reset to default value “1234”
1. Insert the reset jumper into 1-2 (5 beeps)
2. Master Code reset to default value “1234” (must release the jumper as soon as 5 beeps, otherwise
could clear all PINs)
3. Insert the jumper back into 2-3
(Note: Only after 5 beeps, the system will execute the reset process)
Master Code reset to default value“1234” and Clear all PINs
1. Insert the reset jumper into 1-2 (5 beeps)
2. Master Code reset to default value“1234”
3. Clear all PINs (wait after 5 seconds) (5 beeps)
4. Insert the jumper back into 2-3