Ⅲ. Indicator Status & Default Setting Parameters
Beep & LED Indication:
Mode
Status
Green On
Relay Strike Time
Red On
Power on
LED
Yellow On
In setting mode
1 Beep
Key press, valid PINs
2 Beeps
Enter or exit setting mode
3 Beeps
Incorrect input
Beep
5 Beeps
Master Code back to 1234 (cleared settings)
Factory Default Setting:
Master Code
1234 (4 digits)
Relay Strike Time
5 seconds
Pressed Key Time Delay
30 seconds
Setting Mode Time Delay
50 seconds
Ⅳ. Operation Instruction
Enter Setting Mode
Enter the master code twice (Default value:“1234”) to enter setting mode (2 Beeps)
Note: 1. After 50 seconds if no data entered, it will automatically exit the setting mode.
2. The controller will be lockout for 60 seconds upon 30 consecutive master codes or invalid
PINs attempt.
Exit Setting Mode
Press # to exit setting mode or after 50 seconds if no data entered, it will automatically exit the setting
mode.
Add new PINs (In setting mode)
1. Enter slot position*001(*001~*099)
2. Enter the 4-digit PINs (1 beep)
3. Press “#” to exit setting mode
Note: 1. “0000”, “1234” and any master code cannot be used for PINs
2. Up to 29-digit-fuzzy-code password protected design
e.g. Press 59632548745233058403256905194→open the door (The valid PINs are “5194”)