Chapter 3: Maintaining Your Server
www.gateway.com
Setting up paging alerts
To set up paging alerts:
1
Boot your server from the Server Companion CD, then select
System Setup
Utility
from the menu. The System Setup Utility starts.
2
Install an external modem on the serial RJ-45 port on the back of your
server.
3
In the SSU Main window, click
Platform Event Manager (PEM)
.
4
In the PEM window, click
Configure EMP
.
5
In the corresponding boxes, enter the following command strings for the
modem attached to the serial RJ-45 port:
■
ESC Sequence
—The escape sequence. This string is sent to the modem
before sending command strings. The maximum length for the string
is five characters. Longer strings are truncated.
■
Hangup String
—Hang up or drop the connection. The EMP
automatically sends an E
NTER
character following this string. The
maximum length for the string is eight characters.
■
Modem Dial Command
—The command to dial a phone number. This
string is sent to the modem before sending the paging string.
■
Modem Init String
—Initialization string for the modem. Sent every time
the EMP initializes. You will be notified if the string is truncated.
Following a save, the actual string saved is displayed in the edit box.
6
Click
Save
to save the changes.
7
Click
Close
to return to the PEM window.
8
In the PEM window, click
Configure PEP
.
9
Click to select the
Enable PEP
check box.
10
In the
Blackout Period
box, type the minimum time, in minutes, between
successive pages. The valid range is 0-255 where 0 disables the blackout
period.
Setting a blackout period can save you from being flooded with repeat
pages. After you receive a PEP page, no additional pages are sent by PEP
for the duration of the blackout period.