Setting up paging alerts

To set up paging alerts:

1

Boot your server from the Server Companion CD, then select

System Setup

Utility

from the menu. The System Setup Utility starts.

2

Install an external modem on the serial RJ-45 port on the back of your
server.

3

In the SSU Main window, click

Platform Event Manager (PEM)

.

4

In the PEM window, click

Configure EMP

.

5

In the corresponding boxes, enter the following command strings for the
modem attached to the serial RJ-45 port:

ESC Sequence

—The escape sequence. This string is sent to the modem

before sending command strings. The maximum length for the string
is five characters. Longer strings are truncated.

Hangup String

—Hang up or drop the connection. The EMP

automatically sends an E

NTER

character following this string. The

maximum length for the string is eight characters.

Modem Dial Command

—The command to dial a phone number. This

string is sent to the modem before sending the paging string.

Modem Init String

—Initialization string for the modem. Sent every time

the EMP initializes. You will be notified if the string is truncated.
Following a save, the actual string saved is displayed in the edit box.

6

Click

Save

to save the changes.

7

Click

Close

to return to the PEM window.

8

In the PEM window, click

Configure PEP

.

9

Click to select the

Enable PEP

check box.

10

In the

Blackout Period

box, type the minimum time, in minutes, between

successive pages. The valid range is 0-255 where 0 disables the blackout
period.

Setting a blackout period can save you from being flooded with repeat
pages. After you receive a PEP page, no additional pages are sent by PEP
for the duration of the blackout period.