beautypg.com

Gateway ADAC ULTRA2 S466 User Manual

Page 90

background image

ADAC Ultra2 S466 Hardware Guide

76

Message

Problem

Suggested Solution

X Logical Drives
Degraded

x number of logical drives
signed on in a degraded
state.

Make sure all physical
drives are properly
connected and are powered
on.

Run ADAC Configuration
Manager to find if any
physical drives are not
responding. Reconnect,
replace, or rebuild any
drive that is not
responding.

1 Logical Drive Degraded

A logical drive signed on
in a degraded state.

Make sure all physical
drives are properly
connected and are powered
on.

Run ADAC Configuration
Manager to find out if any
physical drives are not
responding. Reconnect,
replace, or rebuild any
drive that is not
responding.

Insufficient memory to
run BIOS. Press any key
to continue…

Not enough ADAC Ultra2
S466 memory to run
BIOS.

Make sure ADAC Ultra2
S466 memory has been
properly installed.

Insufficient Memory

Not enough memory on
the ADAC adapter to
support the current
configuration.

Make ADAC memory has
been properly installed.

The following SCSI IDs
are not responding:
Channel x:a.b.c

The physical drives with
SCSIO IDs a, b, and c are
not responding on SCSI
channel x.

Make sure the physical
drives are properly
connected and are powered
on.