3-60

M3099GX/GH OEM Manual

The window width field specifies the width of window in scan line
direction. The window width is measured using the target’s current
measurement unit divisor.

Window Length:

0 to 20736 [1/1200 inch]

The window length field specifies the length of the window in the
base line direction. The window length is measured using the target’s
current measurement unit divisor.

Note: The relation between X-Axis Resolution, Y-Axis Resolution,

X-Axis Upper Left, Y-Axis Upper Left, Window Width,
Window Length.

Upper Left X field value:

ULX

Upper Left Y field value:

ULY

Width field value:

W

Length field value:

L

X Resolution:

XR

Y Resolution:

YR

1) Maximum Scanning Area limitations

0 < (ULX+W)

14592 [1/1200 inch] for M3099GX

10368 [1/1200 inch] for M3099GH

0 < (ULY+L)

20736 [1/1200 inch]

2) Width and X Resolution limitation

9

(XR

×

W/1200)

4864 [dot] for M3099GX

3456 [dot] for M3099GH

3) Length and Y Resolution limitation

1 £ (YR

×

L/1200)

6912 [line]

4) Horizontal and Vertical limitation (M3099GX only)

if ( 13200(11") < (ULX+W)

14592 )

then 0 < (ULY+L)

19842(A3 length) ;

Brightness:

0 to 255

The brightness field specifies the level of brightness used to scan the
object. A value of zero specifies the default brightness. Any other
value indicates a relative brightness setting with 255 being the
highest setting, one being the lowest setting, and 128 being the
nominal setting.The brightness effects for Halftone image.