beautypg.com

Scan command, Scan command -79, 59 scan command -79 – FUJITSU C150-E049-02EN User Manual

Page 112

background image

M3099GX/GH OEM Manual

3-79

INTERFACE

Destination Table Size:

0100h(255 step)

The destination table size field specifies the range of output value to
Gamma Correction Table.

Gamma Correction Table Data:

The gamma correction table data transfers look up table for image
data to be scanned.

Example - 256 steps of grayscale

INPUT

OUTPUT

ORDER

DATA

0

00h

1

00h

2

00h

3

00h

4

00h

5

00h

6

00h

7

00h

8

00h

9

00h

10

D0

11

D0

12

D0

13

D0

14

D0

15

D0

16

D0

17

D0

263

D253

264

D254

265

D255

D0 to D255 can be any 0 to 255 value. Each data is one byte length.

Endorser Data

See ENDORSER Command.

SCAN Command

The SCAN command (Table 3.59) requests the target begin a scan
operation.

Table 3.59 SCAN Command

Bit

Byte

0

1

2

3

4

5

7

6

5

3

2

1

0

Operation Code (1Bh)

Reserved

Reserved

Transfer Length

Control

Logical Unit Number

Reserved

4

#03.pm5

98.2.22, 1:33 PM

79