Separation pressure adjustment, Appendix c, Appendix c: separation pressure adjustment – FUJITSU C150-E049-02EN User Manual
Page 226

M3099GX/GH OEM Manual
C-1
SEPARATION
PRESSURE
ADJUSTMENT
1 Turn off the power switch.
Make sure that the hopper
table is at the bottom.
2 Open the upper transport unit.
(See page 4-2)
3 Disconnect the two relay
connectors on the roller ASY.
4 Push the two levers (green)
towards each other to dis-
engage with the upper locking
holes and lower down the two
levers until they engage with
the two levers locking holes.
APPENDIX
C
SEPARATION PRESSURE ADJUSTMENT
Adjust the separation pressure as follows:
WARNING
Wait at least 3 minutes after turning off the power before replacement.
ACHTUNG
Warten Sie mindestens 3 Minuten nach Ausschalten, bevor Sie mit dem
Austausch beginnen.
Roller ASY
Lever (green)
Power switch
Operator panel
Upper transport unit
Lever